LEVEL DRYER
Level Dryer
17.
       Not Level 
            
LEVEL                    Not Level
Check levelness of dryer from side to side. Repeat from  
front to back. 
NOTE: The dryer must be level for the moisture sensing system 
to operate correctly.
Place 
level here
Tighten and adjust leveling legs
18. 
If dryer is not level, prop up using a wood block, use wrench  
to adjust legs up or down, and check again for levelness. 
Once legs are level, make sure all four legs are snug against 
the ground before tightening them.
CONNECT VENT
Connect vent to exhaust outlet
15.
Move dryer to final location
16.
Using a 4" (102 mm) clamp, connect vent to exhaust outlet  
in dryer. If connecting to existing vent, make sure vent is 
clean. Dryer vent must fit over dryer exhaust outlet and inside 
exhaust hood. Check that vent is secured to exhaust hood 
with a 4" (102 mm) clamp.
Move dryer to final location.  Avoid crushing or kinking vent. 
After dryer is in place, remove corner posts and cardboard 
from under the dryer.