Whirlpool WGD5700V User Manual

Page of 28
7
gAS DRYER PoWER HooKuP
gas Supply Requirements
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure 
gas pressure does not exceed 13" (330 mm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
gas type
natural gas:
This dryer is equipped for use with Natural Gas. It is design-
certified by CSA International for LP (propane or butane) gases 
with appropriate conversion.
Your dryer must have the correct burner for the type of gas  
 
in your home. Burner information is located on the rating  
plate in the door well of your dryer. If this information does  
not agree with the type of gas available, please reference 
the “Assistance or Service” section of the “Dryer User 
Instructions.” 
lP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the dryer from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier.
ImPoRTAnT: The gas installation must conform with local codes, 
or in the absence of local codes, with the National Fuel Gas 
Code, ANSI Z223.1/NFPA 54 or the Canadian Natural Gas and 
Propane Installation Code, CSA B149.1.
gas supply line
1/2" NPT pipe is recommended.
 
3/8" approved tubing is acceptable for lengths under  
 
20 ft. (6.1 m) if local codes and gas supplier permit.
Must include 1/8" NPT minimum plugged tapping accessible 
 
for test gauge connection, immediately upstream of the gas 
connection to the dryer (see illustration).
Must include a shutoff valve:
 
In the u.S.A.:
An individual manual shutoff valve must be installed within   
six (6) feet (1.8 m) of the dryer in accordance with the 
National Fuel Gas Code, ANSI Z223.1. 
In Canada:
An individual manual shutoff valve must be installed in 
accordance with the B149.1, Natural Gas and Propane 
Installation Code. It is recommended that an individual 
manual shutoff valve be installed within six (6) feet (1.8 m)  
of the dryer.
The shut off valve location should be easy to reach for opening 
and closing.
A
B
E
D
C
A.  3/8" flexible gas connector
B.  3/8" pipe to flare adapter fitting
C.  1/8" NPT minimum plugged tapping
D.  1/2" NPT gas supply line
E.  Gas shutoff valve
gas supply connection requirements
There are many methods by which your gas dryer can be 
connected to the gas supply. Listed here are some guidelines  
for two different methods of connection.
option 1 (Recommended method)
Flexible stainless steel gas connector:
If local codes permit, use a new flexible stainless steel gas 
 
connector (Design Certified by the American Gas Association 
or CSA International) to connect your dryer to the rigid gas 
supply line. Use an elbow and a 3/8" flare x 3/8" NPT adapter 
fitting between the stainless steel gas connector and the 
dryer gas pipe, as needed to prevent kinking.
option 2 (Alternate method)
Approved aluminum or copper tubing:
Lengths over 20 ft. (6.1 m) can use 3/8" approved tubing  
 
(if codes and gas supplier permit).
If you are using Natural Gas, do not use copper tubing.
 
3/8" flare x 3/8" NPT adapter fitting between dryer pipe and 
 
3/8" approved tubing.
Lengths over 20 ft. (6.1 m) should use larger tubing and a 
 
different size adapter fitting.
If your dryer has been converted to use LP gas, 3/8" LP 
 
compatible copper tubing can be used. If the total length  
of the supply line is more than 20 ft. (6.1 m), use larger pipe. 
noTE: Pipe joint compounds that resist the action of LP  
gas must be used. Do not use TEFLON
®†
 tape.