14
Good
Better
Clamps:
Use clamps to seal all joints.
 
Exhaust vent must not be connected or secured with screws 
 
or other fastening devices that extend into interior of duct 
and catch lint. Do not use duct tape.
An exhaust hood should cap vent to keep rodents and 
 
insects from entering home.
Do not use exhaust hood with a magnetic latch.
 
Elbows:
45° elbows provide better airflow than 90° elbows.
 
     
4"
(102 mm)
      
4"
(102 mm)
B
A
   
4"
(102 mm)
2½"
(64 mm)
C
Recommended styles:
A. Louvered hood
B. Box hood
Acceptable styles:
C. Angled hood
Exhaust hoods:
Must be at least 12" (305 mm) from ground or any object that 
 
may obstruct exhaust (such as flowers, rocks, bushes, or 
snow).
 
Flexible metal vent: 
(Acceptable only if accessible to clean)
Must be fully extended and supported in final dryer location.
 
Remove excess to avoid sagging and kinking that may result 
 
in reduced airflow and poor performance.
Do not install in enclosed walls, ceilings, or floors.
 
The total length should not exceed 7
 
3
/
4
 ft. (2.4 m).
noTE: 
If using an existing vent system, clean lint from entire 
length of the system and make sure exhaust hood is not plugged 
with lint. Replace plastic or metal foil vents with rigid metal or 
flexible metal vents. Review Vent system chart and if necessary, 
modify existing vent system to achieve best drying performance. 
vENTINg REQUIREMENTS
WARNING
Fire Hazard
use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death 
or fire.
WARnInG: 
To reduce the risk of fire, this dryer MUST BE 
EXHAUSTED OUTDOORS.
ImPoRTAnT: 
Observe all governing codes and ordinances.
Dryer exhaust must not be connected into any gas vent, 
chimney, wall, ceiling, attic, crawlspace, or a concealed space 
of a building. Only rigid or flexible metal vent shall be used for 
exhausting.
Only a 4" (102 mm) heavy metal exhaust 
vent and clamps may be used. 
Do not use plastic or metal foil vent.
Rigid metal vent:
Recommended for best drying performance and to avoid 
 
crushing and kinking.