Whirlpool mede250 Installation Instruction

Page of 20
6
Closet Installation (stacked washer and dryer):
1"
(25 mm)
1"
(25 mm)
5
1
/
2
"
(140 mm)
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
6"
(152 mm)
76"
(1930 mm)
Custom under counter installation (dryer only):
1"
(25 mm)
1"
(25 mm)
39" min.
(990 mm)
noTE: Some models not recommended for undercounter 
installation.
mobile home - Additional installation requirements: 
This dryer is suitable for mobile home installations. The  
installation must conform to the Manufactured Home  
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile home construction  
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 
MH.
mobile home installations require: 
Metal exhaust system hardware, available for purchase from  
 
your dealer. For further information, see “Assistance or  
Service” section in your Use and Care Guide.
Special provisions must be made in mobile homes to 
 
introduce outside air into dryer. Openings (such as a nearby 
window) should be at least twice as large as dryer exhaust 
opening.
ELECTRICAL REQUIREMENTS
It is your responsibility:
To contact a qualified electrical installer.
 
To be sue that the electrical connection is adequate and in 
 
conformance with the National Electrical Code, ANSI/NFPA 
70 - latest edition and all local codes and ordinances. 
 
The National Electrical Code requires a 4-wire power supply 
connection for homes built after 1996, dryer circuits involved 
in remodeling after 1996, and all mobile home installations. 
 
A copy of the above code standards can be obtained from: 
National Fire Protection Association, One Batterymarch Park, 
Quincy, MA 02269.
To supply the required 3 or 4 wire, single phase, 120/240 
 
volt, 60 Hz, AC only electrical supply (or 3 or 4 wire, 120/208 
volt electrical supply, if specified on the serial/rating plate) 
on a separate 30-amp circuit, fused on both sides of the line. 
Connect to an individual branch circuit. Do not have a fuse in 
the neutral or grounding circuit.
Do not use an extension cord.
 
If codes permit and a separate ground wire is used, it is 
 
recommended that a qualified electrician determine that the 
ground path is adequate.
Electrical Connection
To properly install your dryer, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
This dryer is manufactured ready to install with a 3-wire 
 
electrical supply connection. The neutral ground conductor  
is permanently connected to the neutral conductor (white 
wire) within the dryer. If the dryer is installed with a 4-wire 
electrical supply connection, the neutral ground conductor 
must be removed from the external ground connector (green 
screw), and secured under the neutral terminal (center or 
white wire) of the terminal block. When the neutral ground 
conductor is secured under the neutral terminal (center or 
white wire) of the terminal block, the dryer cabinet is isolated 
from the neutral conductor.
If local codes do not permit the connection of a neutral  
 
ground wire to the neutral wire, see “Optional 3-wire 
connection” section.
A 4-wire power supply connection must be used when the 
 
appliance is installed in a location where grounding through  
the neutral conductor is prohibited. Grounding through the 
neutral is prohibited for (1) new branch-circuit installations,  
(2) mobile homes, (3) recreational vehicles, and (4) areas  
where local codes prohibit grounding through the neutral 
conductors.
If using a power supply cord:
Use a UL listed power supply cord kit marked for use with  
clothes dryers. The kit should contain:
A UL listed 30-amp power supply cord, rated 120/240 volt 
 
minimum. The cord should be type SRD or SRDT and be  
at least 4 ft. (1.22 m) long. The wires that connect to  
the dryer must end in ring terminals or spade terminals  
with upturned ends.
A UL listed strain relief.