Whirlpool mede250 Installation Instruction

Page of 20
9
Put power supply cord through strain relief. Be sure that wire 
insulation on power cord is inside strain relief. Strain relief 
should be a tight fit with dryer cabinet and be in a horizontal 
position. Do not tighten strain relief screws at this point.  
now go to step 5 for 4-wire power supply cord 
connection or step 9 for 3-wire power supply cord 
connection.
Attach power supply cord  
to strain relief
6.
   
 
Attach power supply cord  
     strain relief
Remove screws from 3/4" (19 mm) UL listed strain relief (UL 
marking on strain relief). Put two clamp section tabs into hole 
below terminal block opening with one tab pointing up and 
one pointing down. Hold in place and tighten strain relief 
screws enough to hold two clamp sections together.
5.
A
B
C
D
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
Power supply cord strain relief:
4-wIRE pOwER SUppLY CORD 
CONNECTION
Remove center, silver-colored terminal block screw (B).  
Remove neutral ground wire (E) from external ground 
conductor screw (A).
Prepare to connect neutral  
ground wire and neutral wire.
7.
Connect neutral ground wire 
and neutral wire
8.
Connect neutral ground wire (E) and neutral wire (white or 
center wire) (C) of power supply cord under center, silver-
colored terminal block screw (B). Tighten screw.
E
E
C
ImPoRTAnT: 
A 4-wire connection is required for mobile 
homes and where local codes do not permit the use of 3-wire 
connections. 
A
B
F
E
G
D
C
A.  4-wire receptacle (NEMA type 14-30R)
B.  4-prong plug
C.  Ground prong
D.  Neutral prong
E.  Spade terminals with upturned ends
F.  3/4" (19 mm) UL listed strain relief
G.  Ring terminals
A
B
B