Whirlpool ggw9250p User Guide

Page of 44
12
Level Dryer
Check the levelness of the dryer. Check levelness first 
side to side, then front to back.
If the dryer is not level, prop up the dryer using a wood block. 
Use a wrench to adjust the legs up or down and check again for 
levelness.
NOTE: It might be necessary to level the dryer again after it has 
been moved into its final position.
Make Gas Connection
1. Remove the red cap from the gas pipe. Move the dryer close 
to its final position.
2. Using a wrench to tighten, connect the gas supply to the 
dryer. Use pipe joint compound on all non-flared male 
threads. If flexible metal tubing is used, be sure there are 
no kinks.
NOTE: For L.P. gas connections, you must use pipe joint 
compound resistant to the action of L.P. gas. Do not use 
TEFLON
®†
 tape.
A combination of pipe fittings must be used to connect the 
dryer to the existing gas line. Shown following is a 
recommended connection. Your connection may be different, 
according to the supply line type, size and location.
3. Open the shutoff valve in the supply line. The valve is open 
when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in 
dryer. If connecting to existing vent, make sure the vent is 
clean. The dryer vent must fit over the dryer exhaust outlet 
and inside the exhaust hood. Make sure the vent is secured 
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into final position. Do not crush or kink vent. 
Make sure dryer is level.
3. (On gas models) Check to be sure there are no kinks in the 
flexible gas line.
Complete Installation
1. Check to be sure all parts are now installed. If there is an 
extra part, go back through the steps to see which step was 
skipped.
2. Check to be sure you have all of your tools.
3. Dispose of all packaging materials. 
4. Check the dryer’s final location. Be sure the vent is not 
crushed or kinked.
5. Check to be sure the dryer is level. See “Level Dryer.”
6. Plug into a grounded 3 prong outlet. Turn power on.
7. Remove the blue protective film on the console and any tape 
remaining on the dryer.
8. Read “Dryer Use.”
9. Wipe the dryer drum interior thoroughly with a damp cloth to 
remove any dust.
10. Set the dryer on a full heat cycle (not an air cycle) for 
20 minutes and start the dryer.
If the dryer will not start, check the following:
Dryer is plugged into a grounded 3 prong outlet.
Electrical supply is connected.
House fuse is intact and tight, or circuit breaker has not 
tripped.
Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the 
dryer door and feel for heat. If you do not feel heat, turn the 
dryer off and check to see that the gas supply line shutoff 
valve is open. 
If the gas supply line shutoff valve is closed, open it, then 
repeat the 5-minute test as outlined above.
If the gas supply line shutoff valve is open, contact a 
qualified technician.
A.
³⁄₈
" flexible gas connector
B.
³⁄₈
" dryer pipe 
C.
³⁄₈
" to 
³⁄₈
" pipe elbow
D.
³⁄₈
" pipe-to-flare adapter fitting
A. Closed valve
B. Open valve
A
B
C
D
A