Location Requirements
You will need
A location that allows for proper exhaust installation. A gas 
dryer must be exhausted to the outdoors. See “Venting 
Requirements.”
A grounded electrical outlet located within 2 ft (61 cm) of 
either side of the dryer. See “Electrical Requirements.”
A sturdy floor to support the total dryer weight of 200 lbs 
(90.7 kg). The combined weight of a companion appliance 
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire 
dryer. If slope is greater than 1" (2.5 cm), install Extended 
Dryer Feet Kit, Part Number 279810. Clothes may not tumble 
properly and automatic sensor cycles may not operate 
correctly if dryer is not level.
For a garage installation, you will need to place the dryer at 
least 18" (46 cm) above the floor. If using a pedestal, you will 
need an additional 6" (15.24 cm).
Do not operate your dryer at temperatures below 45ºF (7ºC). At 
lower temperatures, the dryer might not shut off at the end of an 
automatic cycle. This can result in longer drying times.
The dryer must not be installed or stored in an area where it will 
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit, 
installation of the dryer in garages, closets, mobile homes, or 
sleeping quarters. Contact your local building inspector.
NOTE: No other fuel-burning appliance can be installed in the 
same closet as a dryer.
Installation clearances
The location must be large enough to fully open the dryer 
door.
Additional spacing should be considered for ease of 
installation and servicing.
Additional clearances might be required for wall, door and 
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is 
recommended to reduce noise transfer.
Companion appliance spacing should also be considered.
Dryer Dimensions
*Most installations require a minimum 5½" (14 cm) clearance  
behind the dryer for the exhaust vent with elbow. See “Venting  
Requirements.”
Minimum installation spacing for custom undercounter 
installation
The dimensions shown are for the minimum spacing allowed.
Custom undercounter installation - Dryer only
Minimum installation spacing for recessed or closet 
installation, with or without a pedestal
The dimensions shown are for the minimum spacing allowed.
For closet installation, with a door, minimum ventilation 
openings in the top and bottom of the door are required. 
Louvered doors with equivalent ventilation openings are 
acceptable.
WARNING
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage installation.
Failure to do so can result in death, explosion, or fire.
      38"
(96.52 cm)
 *31½"
(80 cm)
     27"
(68.6 cm)
     51½"
(130.81 cm)
    0"
(0 cm)
    0"
(0 cm)
    0"
(0 cm)
  38" min.
(96.52 cm)
     27"
(68.6 cm)