Whirlpool ggw9250s User Guide

Page of 48
13
A combination of pipe fittings must be used to connect the 
dryer to the existing gas line. Shown is a recommended 
connection. Your connection may be different, according to 
the supply line type, size and location.
3. Open the shutoff valve in the supply line. The valve is open 
when the handle is parallel to the gas pipe.
4. Test all connections by brushing on an approved 
noncorrosive leak-detection solution. Bubbles will show a 
leak. Correct any leak found.
Connect Vent
1. Using a 4" (10.2 cm) clamp, connect vent to exhaust outlet in 
dryer. If connecting to existing vent, make sure the vent is 
clean. The dryer vent must fit over the dryer exhaust outlet 
and inside the exhaust hood. Make sure the vent is secured 
to exhaust hood with a 4" (10.2 cm) clamp.
2. Move dryer into its final location. Do not crush or kink vent.
3. (On gas models) Check that there are no kinks in the flexible 
gas line.
4. Once the exhaust vent connection is made, remove the 
corner posts and cardboard.
Complete Installation
1. Check that all parts are now installed. If there is an extra part, 
go back through the steps to see which step was skipped.
2. Check that you have all of your tools.
3. Dispose of/recycle all packaging materials. 
4. Check the dryer’s final location. Be sure the vent is not 
crushed or kinked.
5. Check that the dryer is level. See “Level Dryer.”
6. Plug into a grounded 3 prong outlet. Turn on power.
7. Remove any protective film or tape remaining on the dryer.
8. Read “Dryer Use.”
9. Wipe the dryer drum interior thoroughly with a damp cloth to 
remove any dust.
10. Select a Timed Dry heated cycle, and start the dryer. Do not 
select the Air Only Temperature setting.
If the dryer will not start, check the following:
Dryer is plugged into a grounded 3 prong outlet.
Electrical supply is connected.
Household fuse is intact and tight, or circuit breaker has 
not tripped.
Dryer door is closed.
11. When the dryer has been running for 5 minutes, open the 
dryer door and feel for heat. If you feel heat, cancel cycle and 
close door. If you do not feel heat, turn off the dryer and 
check that the gas supply line shutoff valve is open.
If the gas supply line shutoff valve is closed, open it, then 
repeat the 5-minute test as outlined above.
If the gas supply line shutoff valve is open, contact a 
qualified technician.
A.
³⁄₈
" flexible gas connector
B.
³⁄₈
" dryer pipe 
C.
³⁄₈
" to 
³⁄₈
" pipe elbow
D.
³⁄₈
" pipe-to-flare adapter fitting
A. Closed valve
B. Open valve
A
B
C
D
A
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING