Whirlpool ggw9250s User Guide

Page of 48
8
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The 
installation must conform to the Manufactured Home 
Construction and Safety Standard, Title 24 CFR, Part 3280 
(formerly the Federal Standard for Mobile Home Construction 
and Safety, Title 24, HUD Part 280) or Standard CAN/CSA-Z240 
MH.
Mobile home installations require:
Metal exhaust system hardware, which is available for 
purchase from your dealer.
Mobile Home Installation Kit Part Number 346764. See “Tools 
and Parts” section for ordering information.
Special provisions must be made in mobile homes to 
introduce outside air into the dryer. The opening (such as a 
nearby window) should be at least twice as large as the dryer 
exhaust opening.
Electrical Requirements
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical 
supply is required. A time-delay fuse or circuit breaker is 
recommended. It is also recommended that a separate circuit 
serving only this dryer be provided.
Gas Supply Requirements
Gas Type
Natural gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases 
with appropriate conversion.
Your dryer must have the correct burner for the type of gas in 
your home. Burner information is located on the rating plate 
in the door well of your dryer. If this information does not 
agree with the type of gas available, contact your dealer or 
call the phone numbers referenced in the “Assistance or 
Service” section of this manual.  
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the appliance from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting your gas company.
Gas supply line
Must include 
¹⁄₈
"
NPT minimum plugged tapping accessible 
for test gauge connection, immediately upstream of the gas 
connection to the dryer (see illustration).
¹⁄₂" IPS pipe is recommended.
³⁄₈" approved aluminum or copper tubing is acceptable for 
lengths under 20 ft (6.1 m) if local codes and gas supplier 
permit.
If you are using Natural gas, do not use copper tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and a 
different size adapter fitting.
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING
GROUNDING INSTRUCTIONS
SAVE THESE  INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment-
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: 
Improper connection of the equipment-
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with the 
dryer: if it will not fit the outlet, have a proper outlet installed 
by a qualified electrician.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure
gas pressure does not exceed 13" (33 cm) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.