Dryer gas pipe
The gas pipe that comes out through the rear of your dryer has a 
3
/
8
" male pipe thread.
A.
1
/
2
" NPT gas supply line
B.
3
/
8
" NPT dryer pipe
   
A
B
    *6¼"
(159 mm)
   1½"
(38 mm)
*NOTE: If the dryer is mounted on a pedestal, the gas pipe 
 
height must be an additional 10" (254 mm) or 15.5" (394 mm) 
from the floor, depending on the pedestal model. For a garage 
installation, the gas pipe height must be an additional 
18" (457 mm) from the floor.
Make Gas Connection
1. Remove the red cap from the gas pipe. 
2. Using a wrench to tighten, connect the gas supply to the dryer. 
Use pipe-joint compound on the threads of all non-flared male 
fittings. If flexible metal tubing is used, be sure there are no kinks.
A
B
A. Flared male fitting
B. Non-flared male fitting
NOTE: For LP gas connections, you must use pipe-joint 
compound resistant to the action of LP gas. Do not use 
TEFLON
®†
®TEFLON  is a registered trademark of E.I. Du Pont De Nemours and Company.
 tape.
A combination of pipe fittings must be used to connect the dryer 
to the existing gas line. Shown is a recommended connection. 
Your connection may be different, according to the supply line 
type, size and location.
A.
3
/
8
" flexible gas 
connector
B.
3
/
8
" dryer pipe 
C.
3
/
8
" to 
3
/
8
" pipe elbow
D.
3
/
8
" pipe-to-flare 
adapter fitting
A
B
C
D
3. Open the shutoff valve in the supply line. The valve is open when 
the handle is parallel to the gas pipe.
A. Closed valve
B. Open valve
A
B
 
4. Test all connections by brushing on an approved noncorrosive 
leak-detection solution. Bubbles will show a leak. Correct any 
 
leak found.
Electrical Requirements
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, 
fire, or electrical shock.
WARNING
120 Volt, 60 Hz., AC only, 15- or 20-amp fused electrical 
supply is required. A time-delay fuse or circuit breaker is 
recommended. It is also recommended that a separate circuit 
serving only this dryer be provided.
GROUNDING INSTRUCTIONS
SAVE THESE INSTRUCTIONS
■  
For a grounded, cord-connected dryer: 
This dryer must be grounded. In the event of malfunction or 
breakdown, grounding will reduce the risk of electric shock 
by providing a path of least resistance for electric current. 
This dryer is equipped with a cord having an equipment- 
grounding conductor and a grounding plug. The plug must 
be plugged into an appropriate outlet that is properly 
installed and grounded in accordance with all local codes 
and ordinances.
WARNING: 
Improper connection of the equipment- 
grounding conductor can result in a risk of electric shock. 
Check with a qualified electrician or service representative 
or personnel if you are in doubt as to whether the dryer is 
properly grounded. Do not modify the plug provided with 
the dryer: if it will not fit the outlet, have a proper outlet 
installed by a qualified electrician.