Bunn FMD-1 User Guide

Page of 43
37
J1
TANk HEATER - FMD-1 (shown) & FMD-2
FIG. 40 TANK HEATER
Location:
 
The tank heater is located inside the tank and 
secured to the tank lid.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Check the voltage across the black and white wires 
120 volt or 230 volt models or black and red wires 
for 120/208 volt  models or 120/240 volt models 
with a voltmeter. Connect the dispenser to the power 
source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models,
 
b)  120  volts  ac  for  three  wire  120/208  volt  or 
120/240 volt models,
 
c) 230 volts ac for two wire 230 volt models, after 
a delay of approximately 5 seconds.
3.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to the dis-
penser wiring diagram and check the wiring harness.
4.  Disconnect the black wire and the white or red  wire 
from the tank heater terminals.
5.  Check for continuity across the tank heater termi-
nals.
If  continuity  is  present  as  described,  reconnect  the 
wires, the tank heater is operating properly.
If continuity is not present as described, replace the 
tank heater.
P1665
P1217
FIG. 39 INLET SOLENOID VALVE TERMINALS
SERVICE (cont.)
SOLENOID VALVE (INLET) - FMD-1 & FMD-2 
(cont.)
WHI from Main Harness
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not 
pass through the solenoid valve, there may be a block-
age in the water line before the solenoid valve or, the 
solenoid valve may require inspection for wear, and 
removal of waterborne particles.
If  the  sound  is  not  heard  as  described,  replace  the 
solenoid valve.
Removal and Replacement:
1.  Remove the white and violet wires from the solenoid 
valve.
2.  Turn-off the water supply to the dispenser.
3.  Disconnect the water lines to and from the solenoid 
valve.
4.  Remove the two #8-32 screws securing the sole-
noid to the rear of the dispenser housing. Remove 
solenoid. 
5.  Remove the two #8-32 U-Type fasteners from the 
solenoid bracket.
6.  Install the two #8-32 U-Type fasteners and the two 
#8-32 screws on the new solenoid.
7.  Install new solenoid on rear of dispenser housing 
and tighten the two screws
8.  Securely  fasten  the  water  lines  to  and  from  the 
solenoid valve.
9.Refer to Fig. 39 and reconnect the wires.
VIO from Main Harness
29112 091307