Bunn FMD-1 User Guide

Page of 43
39
SERVICE (cont.)
FIG. 43 TANK HEATER SWITCH TERMINALS
P1219
BLK to Main
Harnesss
BLK from Main
Harness
TRANSFORMER - FMD-2 ONLY
FIG. 44 TRANSFORMER
P1666
Location:
 
The transformer is located behind the lower 
front access cover, mounted on the right rear side of 
the component bracket.
Test Procedure:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the four pin plug from the main harness 
from the four pin connector on the transformer.
3  Check the voltage across black wire pin 1 and the
 
white wire pin 2 on the plug from the main har-
ness. Connect the dispenser to power source. The 
indication must be:
 
a) 120 volts ac for two wire 120 volt models,
 
b)  120  volts  ac  for  three  wire  120/208  volt  or 
120/240 volt models,
 
c) 230 volts ac for two wire 230 volt models, after 
a delay of approximately 5 seconds.
4.  Disconnect the dispenser from the power source.
If voltage is present as described reconnect the plug 
and the connector and proceed to #5.
If voltage is not present as described, refer to the wiring 
diagrams and check the main wiring harness.
5.  Check the voltage between J1-1 and J1-2 on the 
eight pin connector at the control board. Connect 
the dispenser to the power source. The indication 
must be 24 volts ac.
If voltage is present as described the transformer is 
operating properly.
If  voltage  is  not  present  as  described,  replace  the 
transformer.
Removal and Replacement:
1.  Loosen the two #8-32 screws securing the com-
ponent bracket to the dispenser housing base.
2.  Pull component bracket out the front of the dispenser 
far enough so the transformer connector can be 
disconnected from the main wiring harness.
3  Disconnect the transformer four pin connector from 
the four pin plug on the main wiring harness.
4.  Remove the two #6-32 keps nuts securing the trans-
former to the rear of the component bracket.
5.  Remove and discard the transformer.
6.  Install new transformer on the rear of the component 
bracket and secure with two #6-32 keps nuts.
7.  Connect the four pin connector on the transformer 
to four pin plug on the main wiring harness.
8.   Place  the  component  bracket  into  position  and 
tighten the two #8-32 screws.
WHI/BLK - T12
WHI/GRN - T7
WHI - 120V T2, 240V T6
BLK - TI
FIG. 45  TRANSFORMER TERMINALS
P1703
29112 101598