SOLENOID VALVE (COLD WATER - OPTIONAL)
FIG. 29 COLD WATER SOLENOID VALVE
P2635
Location:
 
The cold water solenoid valve is located on the left 
side of the dispenser base just behind the component 
bracket.
Test Procedures:
1.   Disconnect  the  dispenser  from  the  power 
source.
2.  Disconnect the white and white/yellow wires from 
the solenoid valve. With the “HOT/COLD” switch 
in  the  “COLD”  (upper)  position  press  the    left 
dispense switch on front of the door.
3.  With a voltmeter, check the voltage across the white 
and white/yellow wires. Connect the dispenser to 
the power source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models, three 
wire 120/208 volt, and 120/240 volt models.
 
b) 240 volts ac for two wire 240 volt models.
 
c) 230 volts ac for two wire 230 volt models.
4.  Disconnect  the  dispenser    from  the  power 
source.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to Wiring 
Diagrams and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If continuity is present as described, reconnect the 
white and white/yellow wires to the solenoid.
If continuity is not present as described, replace the 
solenoid valve.
6.  Check the solenoid valve for coil action. Connect the 
dispenser to the power source. With “HOT/COLD” 
switch in the “COLD” (upper) position press the left 
dispense switch and listen carefully in the vicinity of 
the solenoid valve for a “clicking” sound  as the coil 
magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not pass 
through the solenoid valve, there may be a blockage in 
the water line before the solenoid valve or, the solenoid 
valve may require inspection for wear, and removal of 
waterborne particles.
If the sound is not heard as described, replace the so-
lenoid valve.
Removal and Replacement:
1.  Loosen  the  two  screws  securing  the  component 
bracket to the dispenser base. Lift the component 
bracket off of the base and move to the right.
2.  Remove the white and white/yellow wires from the 
solenoid valve.
3.  Turn off the water supply to the dispenser.
4.  Disconnect the water lines to and from the solenoid 
valve.
5.  Loosen the two #8-32 screws and washers securing 
the solenoid mounting bracket to the base. Remove 
solenoid bracket and solenoid valve as an assem-
bly.
6.  Remove the two #10-32 screws and lockwashers se-
curing the solenoid valve to the solenoid bracket.
7.  Using two #10-32 screws and lockwashers install 
new  solenoid valve on solenoid mounting bracket.
8.  Install  the  solenoid  valve  and  bracket  on  the  dis-
penser base and tighten the two #8-32 screws.  
9.  Securely fasten the water lines to and from the so-
lenoid valve.
10. Refer to Fig. 30 when reconnecting the wires.
SERVICE (cont.)
P1215
WHI/YEL to Hot/
Cold Switch
WHI to Main Wiring 
Harness
FIG. 30 COLD WATER SOLENOID TERMINALS