SERVICE (cont.)
FIG. 32 DISPENSE SOLENOID VALVE 
TERMINALS
P1672
Removal and Replacement:
1.  Remove the four #8-32 screws securing the side 
access panel to the housing. Remove panel and 
set aside.
2.  Remove the wires from the solenoid valve.
3.  Turn-off the water supply to the dispenser.
4.  Using the tank drain tube, drain enough water from 
the tank so the water level is below the dispense 
valve mounting hole.
5.  Disconnect  the  water  line  from  the  solenoid 
valve.
6.  Remove the  #8-32 keps nut securing the solenoid 
valve bracket to side of the tank. Remove solenoid 
valve. 
7.  Install new solenoid valve and o-ring on side of 
the tank and secure in place with valve mounting 
bracket and #8-32 keps nut.
8.  Push the water line onto the tube on bottom of 
solenoid valve.
9.  Refer to Fig. 32 and reconnect the wires.
10. Reinstall side access panels.
SOLENOID VALVE (DISPENSE) - FMD-4 & FMD-5 
(cont.)
WHIto Main Harness
TAN to Main Harness Station #1
RED to Main Harness Station #2
ORN to Main Harness Station #3
YEL to Main Harness Station #4
BLU to Main Harness Station #5
35135 012103