Parts Manual 
 
 
3.  Drain Water Tempering Kit P/N13470.00 Instructions 
 
 
 
 
 
 
1.  Attach the  2 foot 3/8”conduit (1) to a 7/8” hole in the back of the control box. 
2.  Attach two violet wires coming through the conduit, to the sani/rinse terminals on the terminal block. 
3.  Mount solenoid valve (7) mounting bracket on the top of the machine next to rinse solenoid valve. 
4.  Attach flex fitting (4) to the overflow chute. 
5.  Attach 1/4” cold water copper line (not supplied) to the compression fitting (8). 
 
 
 
 
MODEL CMA-66 PARTS MANUAL rev. 2.09                                                                                                Page