Netgear M6100 – Campus Edge and SMB Core Chassis Switches User Guide
Maintenance
533
M6100 Web Management User Guide
Reply From a.b.c.d: icmp_seq = 0. time= xyz usec.
Reply From a.b.c.d: icmp_seq = 1. time= abc usec.
Reply From a.b.c.d: icmp_seq = 2. time= def usec.
Tx = count, Rx = count Min/Max/Avg RTT = xyz/abc/def msec
To access the Ping IPv4 page, click Maintenance
Troubleshooting
Ping IPv4
.
To configure the settings and ping a host on the network:
1.
Use IP Address/Host Name to enter the IP address or Hostname of the station you
want the switch to ping. The initial value is blank.
2.
Enter the Count, the number of echo requests you want to send. The initial value is the
default value. The default value is 3. The range is 1 to 15.
3.
Enter the Interval between ping packets in seconds. The initial value is the default value.
The default value is 3 seconds. The range is 1 to 60.
4.
Enter the Datagram Size of ping packet. The initial value is the default value. The default
value is 0 bytes. The range is 0 to 65507.
5.
Enter the Source IP address or interface to use when sending the echo request packets. If
source is not required, select None as the source option. Possible values are:
•
None
—
The source address of the ping packet would be the address of the default
outgoing interface.
•
IP Address
—
The source IP address to use when sending the Echo request packets.
This field is shown when IP Address is selected as the source option.
•
Interface
—
The interface to use when sending the Echo request packets. This field is
shown when Interface is selected as the source option.
Note:
Values configured in the fields above are not saved to the switch. As a
result, refreshing the page sets these fields to the default values.