Netgear M5300-52G3 (GSM7352Sv2h2) - ProSAFE 48 ports managed L3 gigabit stackable switch Software Guide

Page of 1265
Utility Commands 
309
 M5300, M6100, and M7100 Series ProSAFE Managed Switches
Command example: 
(NETGEAR Switch)#show power
Chassis power:
Total available power(W): ..................... 910
Total required system power(W): ............... 220
Total consumption power(W): ................... 2550
System Power(W): .............................. 220
Power auto-rebalance: ......................... Disable
Power Module AC Input: ........................ 220V
Power module redundancy (N+1): ................ Disable
                          Current      Blade
      Blade               power        power
Slot  Type   Blade Model  consumption  Required   Blade status
----  -----  -----------  -----------  ---------  ----------------
2     3      XCM8948      50 W         50 W       OK
3     2      XCM8944F     330 W        110 W      OK
power cycle 
This command power cycles the blade, waits a few seconds, and then powers on the blade 
again.
power rebalance
This command powers down a low priority PD device until enough power is obtained to 
power up a new blade. 
If all PD devices are shut down but power is still not available, the switch generates the 
following error message on the console and in the logging buffer:
Insufficient power, Blade on Slot <slot number> not powered up
Format
power cycle slot
Mode
Privileged EXEC
Format
power rebalance
Mode
Privileged EXEC