Netgear M5300-52G3 (GSM7352Sv2h2) - ProSAFE 48 ports managed L3 gigabit stackable switch Software Guide
Utility Commands
309
M5300, M6100, and M7100 Series ProSAFE Managed Switches
Command example:
(NETGEAR Switch)#show power
Chassis power:
Total available power(W): ..................... 910
Total required system power(W): ............... 220
Total consumption power(W): ................... 2550
System Power(W): .............................. 220
Power auto-rebalance: ......................... Disable
Power Module AC Input: ........................ 220V
Power module redundancy (N+1): ................ Disable
Current Blade
Blade power power
Slot Type Blade Model consumption Required Blade status
---- ----- ----------- ----------- --------- ----------------
2 3 XCM8948 50 W 50 W OK
3 2 XCM8944F 330 W 110 W OK
power cycle
This command power cycles the blade, waits a few seconds, and then powers on the blade
again.
again.
power rebalance
This command powers down a low priority PD device until enough power is obtained to
power up a new blade.
power up a new blade.
If all PD devices are shut down but power is still not available, the switch generates the
following error message on the console and in the logging buffer:
following error message on the console and in the logging buffer:
Insufficient power, Blade on Slot <slot number> not powered up
Format
power cycle slot
Mode
Privileged EXEC
Format
power rebalance
Mode
Privileged EXEC