Netgear M5300-52G3 (GSM7352Sv2h2) - ProSAFE 48 ports managed L3 gigabit stackable switch Software Guide

Page of 1265
Utility Commands 
311
 M5300, M6100, and M7100 Series ProSAFE Managed Switches
Command example: 
(NETGEAR Switch) #dir USB:
Filename Filesize  Modification Time
F1.cfg    256      4/22/2009 8:00:12
Total Size: xxxx
Bytes Used: yyyy
Bytes Free: zzzz
sFlow Commands
sFlow is the standard for monitoring high-speed switched and routed networks. sFlow 
technology is built into network equipment and gives complete visibility into network activity, 
enabling effective management and control of network resources. 
sflow receiver
Use this command to configure the sFlow collector parameters (owner string, receiver 
time-out, max datagram size, IP address, and port).
Format
sflow receiver rcvr_idx {owner owner-string {timeout rcvr_timeout | 
notimeout} | maxdatagram size | ip ip | port port}
Mode
Global Config
Parameter
Description
Receiver Owner
The identity string for the receiver, the entity making use of this sFlowRcvrTable entry. The range is 
127 characters. The default is a null string. The empty string indicates that the entry is currently 
unclaimed and the receiver configuration is reset to the default values. An entity wishing to claim an 
sFlowRcvrTable entry must ensure that the entry is unclaimed before trying to claim it. The entry is 
claimed by setting the owner string to a non-null value. The entry must be claimed before assigning 
a receiver to a sampler or poller.
Receiver Timeout
The time, in seconds, remaining before the sampler or poller is released and stops sending samples 
to receiver. A management entity wanting to maintain control of the sampler is responsible for setting 
a new value before the old one expires. The allowed range is 0-2147483647 seconds. The default is 
zero (0).
No Timeout 
 
The configured entry will be in the config until you explicitly removes the entry.
Receiver Max 
Datagram Size
The maximum number of data bytes that can be sent in a single sample datagram. The 
management entity should set this value to avoid fragmentation of the sFlow datagrams. The 
allowed range is 200 to 9116). The default is 1400.
Receiver IP
The sFlow receiver IP address. If set to 0.0.0.0, no sFlow datagrams will be sent. The default is 
0.0.0.0.
Receiver Port
The destination Layer4 UDP port for sFlow datagrams. The range is 1-65535. The default is 6343.