Netgear GSM7252PS - ProSAFE 52 ports Gigabit Ethernet L2 Managed Stackable Switch with PoE Hardware Manual

Page of 39
6
   
|   
Chapter 1:  Introduction  
Managed Stackable Switches GSM7200PS and GSM7300S Series Hardware Installation Guide
Table 1-1.  LED Descriptions for GSM7228PS  
LED
Description
ID
This is the stack member ID (1–8) that the software assigns to the switch.
Power 
• 
Solid green: The power module is present, is supplying power to the switch, and 
is working normally.
• 
Solid yellow: The system is in boot-up stage.
• 
Blinking yellow: POS/CPU system has failed. 
• 
Off: Power is disconnected. 
Fan
• 
Solid green: The fan is operating normally.
• 
Solid yellow: The fan has failed.
• 
Off: No fan is detected. 
RPS 
(redundant power 
supply)
• 
Solid green: The redundant power supply is connected and drawing power from 
the power module. 
• 
Solid yellow: The power module power has failed or been disconnected, but the 
redundant power supply is providing power to the switch. 
• 
Blinking yellow: The redundant power supply is present, but the power has 
failed.
• 
Off: The redundant power supply is disconnected or not present.
Stack Master 
• 
Green: The switch acts as a master unit in a stack of GSM7200PS series 
switches.
• 
Off: The switch acts as a slave unit in a stack of GSM7200PS series switches.
PoE Max
• 
Solid yellow: Indicates less than 7W of PoE power is available. 
• 
Blinking yellow: Indicates the PoE MAX LED was active in the previous 2 
minutes. 
• 
Off: There is at least 7W of PoE power available for another device.
M1, M2
High-Speed I/O 
Modules 
(1 LED per module)
• 
Off: Either no module is connected, or a module is connected but not linked to 
the system.
• 
Solid green: A module is present and is linked with the system.
• 
Blinking green: The port is transmitting or receiving packets.