KitchenAid 30" Wall-Mount Canopy Hood Installation Guide

Page of 28
4
INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
Tools needed
Level
Drill 
1¼" (3 cm) drill bit
For chimney mounting brackets: 
³⁄₃₂" (2.4 mm) drill bit if 
installing into wood.
For range hood assembly mounting brackets: 
¹⁄₈" (3 mm) drill 
bit if installing into wood.
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Scissors
Parts needed
Home power supply cable
1 - ½" (12.7 mm) UL listed or CSA approved strain relief
2 UL listed wire connectors
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also 
need:
Chimney Kit Part Number 8212713 (Stainless Steel), 8212714 
(White), or 8212715 (Black). See “Assistance or Service” 
section to order.
Charcoal Filter Kit Part Number 8285507 for non-vented 
(recirculating) installations only. See “Assistance or Service” 
section to order.
Parts supplied
Remove parts from packages. Check that all parts are included.
2 metal grease filters for 30" (76.2 cm) models
3 metal grease filters for 36" (91.4 cm) models
2 - chimney mounting brackets
4 - #10 Phillips head chimney bracket mounting screws
2 - #10 Phillips head range hood mounting screws
6 - Chimney cover mounting screws
Upper chimney cover
Lower chimney cover
Damper
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the 
installer's responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial rating 
plate is located inside the range hood on the rear wall of the 
range hood.
Canopy range hood location should be away from strong draft 
areas, such as windows, doors and strong heating vents. 
Cabinet opening dimensions that are shown must be used. Given 
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical 
Requirements” section.
The canopy range hood is factory set for venting through the roof 
or through the wall. For non-vented (recirculating) Installation see 
“Non-vented (recirculating) Installations” in “Install Range Hood” 
section. Charcoal Filter Kit Part Number 8285507 is available 
from your dealer or an authorized parts distributor. 
All openings in ceiling and wall where canopy range hood will be 
installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the 
Manufactured Home Construction Safety Standards, Title 24 
CFR, Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when such 
standard is not applicable, the standard for Manufactured Home 
Installation 1982 (Manufactured Home Sites, Communities and 
Setups) ANSI A225.1/NFPA 501A*, or latest edition, or with local 
codes.
Product Dimensions
Vented Installations
30" (76.2 cm)
36" (91.4 cm)
22" (55.9 cm)
Min 27
¹⁄₂
" (69.8 cm)
Max 36
¹⁄₂
" (92.7 cm)
21
¹⁄₄
" (54.0 cm)
1
¹⁄₄
"
(3.2 cm)
 
3
¹⁵⁄₁₆
"
(10.0 cm)
10
¹⁄₄
" (26.0 cm)
11
¹³⁄₁₆
" (30.0 cm)