Venting Methods
This canopy range hood is factory set for venting through the roof 
or through the wall.
A 6" (15.2 cm) round vent system is needed for installation (not 
included). The hood exhaust opening is 6" (15.2 cm) round.
NOTE: Flexible vent is not recommended. Flexible vent creates 
back pressure and air turbulence that greatly reduce 
performance.
Vent system can terminate either through the roof or wall. To vent 
through a wall, a 90° elbow is needed.
Rear discharge
A 90° elbow may be installed immediately above the hood.
For non-vented (recirculating) installations
If it is not possible to vent cooking fumes and vapors to the 
outside, the hood can be used in the non-vented (recirculating) 
version, fitting an activated carbon filter and the deflector. Fumes 
and vapors are recycled through the top grille.
Calculating Vent System Length
To calculate the length of the system you need, add the 
equivalent feet (meters) for each vent piece used in the system.  
Maximum equivalent vent length is 35 ft (10.7 m).
Example vent system
The following example falls within the maximum recommended 
vent length of 35 ft (10.7 m).
Electrical Requirements
Observe all governing codes and ordinances. 
Ensure that the electrical installation is adequate and in 
conformance with National Electrical Code, ANSI/NFPA 70 (latest 
edition), or CSA Standards C22.1-94, Canadian Electrical Code, 
Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes 
and ordinances.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrician determine that the 
ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
A 120 Volt, 60 Hz., AC only, 15-amp, fused electrical circuit is 
required.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail 
leads.
2. Connect the aluminum wiring to the added section of 
copper wire using special connectors and/or tools 
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended 
procedure. Aluminum/copper connection must conform with 
local codes and industry accepted wiring practices.
Wire sizes and connections must conform with the rating of 
the appliance as specified on the model/serial rating plate. 
The model/serial plate is located behind the filter on the rear 
wall of the hood.
Wire sizes must conform to the requirements of the National 
Electrical Code, ANSI/NFPA 70 (latest edition), or CSA 
Standards C22. 1-94, Canadian Electrical Code, Part 1 and 
C22.2 No. 0-M91 (latest edition) and all local codes and 
ordinances.
Roof Venting
Wall Venting
Non-vented 
(recirculating)
A. Roof cap
B. 6" (15.2 cm) 
round vent
A. Wall cap
B. 6" (15.2 cm) 
round vent
A. Deflector
B. 6" (15.2 cm) 
round vent
Vent Piece
6" (15.2 cm) Round
45° elbow
2.5 ft
(0.8 m) 
90° elbow
5.0 ft
(1.5 m)
A
A
B
B
B
A
1 - 90° elbow
= 5.0 ft (1.5 m)
1 - wall cap
= 0.0 ft (0.0 m)
8 ft (2.4 m) straight
= 8.0 ft (2.4 m)
Length of system
= 13.0 ft (3.9 m)
90  elbow
6 ft (1.8 m)
2 ft
(0.6 m)
Wall cap