Part 1 - INSTALLATION INSTRUCTIONS
1  -  GENERAL  INFORMATION
This hood has been designed to be wall-mounted above a cooking hob. It can be
installed under a wall unit or directly onto a wall. It can work either by ducting system
(external discharge) or filter (internal recirculation). Before starting the installation,
consideration should be given to the difficulties to be found during installation.
The installation work must be undertaken by a qualified and competent person
in conformity to the rules concerning the evacuation of contaminated air. The
manufacturer disclaims all liability for any damage or injury caused as a result
of not following the instructions for installation contained in the following text.
2  -  SAFETY  WARNINGS
2.1  - When  used  in  the  extraction  mode,  the  cooker  hood  ducting  must  not  be  connected
to  a  flue  which  is  used  for  exhausting  fumes  from  appliances  supplied  with  energy
other  than  electric,  such  as  a  central  heating  flue  or  water  heating  flue.
2.2  - Before  connecting  to  the  mains  supply  ensure  that  the  mains  voltage  corresponds
with  the  voltage  on  the  rating  plate  inside  the  hood.
2.3  - Connect  the  cooker  hood  to  the  mains  via  a  bipolar  switch  which  has  3mm
clearance  between  the  contacts.
2.4  - The  device  does  not  require  earthing,  as  it  is  double-insulated.
2.5  - When  installed,  the  hood  must  be  positioned  at  least  65  cm  above  the  hotplate.
2.6  - Never  do  flambé  cooking  under  this  cooker  hood.
2.7  - Never  leave  frying  pans  unattended  during  use  as  overheated  fat  and  oil  may  catch
fire.
2.8  - Before  carrying  out  any  kind  of  maintenance  or  cleaning,  disconnect  the  hood  from
the  mains  supply.
2.9  - If  the  room  where  the  cooker  hood  is  to  be  used  contains  a  fuel  burning  appliance
such  as  a  central  heating  boiler  then  this  must  be  of  the  room  sealed  or  balanced
flue  type.  If  other  types  of  flue  or  appliance  are  fitted,  ensure  that  there  is  an
adequate  supply  of  air  into  the  room.  When  the  cooker  hood  is  used  in  conjunction
with  appliances  supplied  with  energy  other  than  electric,  the  negative  pressure  in
the  room  must  not  exceed  0,04  mbar  to  prevent  fumes  being  drawn  back  into  the
room  by  the  cooker  hood.
3  -  INSTALLATION
3.1  -  Wall  installation
The hood can be supplied with two different fixing kits:
a) screws,  plugs and safety square.
b) screws, plugs and metal brackets.