Zanussi ZBB28651SA User Manual

Page of 12
Problem
Possible cause
Solution
The compressor does not start
immediately after pressing the
QuickFreeze, or after changing
the temperature.
This is normal, no error has
occurred.
The compressor starts after a pe-
riod of time.
Water flows inside the refriger-
ator.
The water outlet is clogged.
Clean the water outlet.
Food products prevent that
water flows into the water
collector.
Make sure that food products do
not touch the rear plate.
Water flows on the floor.
The melting water outlet is
not connected to the evapo-
rative tray above the com-
pressor.
Attach the melting water outlet to
the evaporative tray.
The temperature in the appli-
ance is too low/too high.
The temperature regulator is
not set correctly.
Set a higher/lower temperature.
The door is not closed cor-
rectly.
Refer to "Closing the door".
The food products' tempera-
ture is too high.
Let the food products tempera-
ture decrease to room tempera-
ture before storage.
Many food products are stor-
ed at the same time.
Store less food products at the
same time.
The door has been opened
often.
Open the door only if necessary.
There is no cold air circula-
tion in the appliance.
Make sure that there is cold air
circulation in the appliance.
If the advice does not lead to the
desired result, contact the nearest
Authorised Service Centre.
REPLACING THE LAMP
The appliance is equipped with a longlife LED
interior light.
Only service is allowed to replace the lighting
device. Contact your Authorised Service Centre.
CLOSING THE DOOR
1. 
Clean the door gaskets.
2. If necessary, adjust the door. Refer to assembly
instructions.
3. If necessary, replace the defective door
gaskets. Contact the Authorised Service
Centre.
INSTALLATION
WARNING! Refer to Safety chapters.
LOCATION
Refer to the assembly instructions for
the installation.
9