Cisco Cisco Prime Optical 10.6 Developer's Guide
Cisco Prime Optical 10.6 GateWay/CORBA Programmer Reference Guide
574
Attribute Name
Type
Supported by Prime Optical?
This is not defined
by the TMF.
The value of this field is the native NE
event value.
event value.
5.3.6 Threshold Crossing Alert
The following table lists the TCA types and attributes.
Table 5-12: Threshold Crossing Alert
Attribute Name
Type
Supported by Prime Optical?
notificationId
String
Yes. The uniqueness and the sequence of the
notification ID are not guaranteed.
notification ID are not guaranteed.
objectName
globaldefs::NamingAttributes_T
Yes.
nativeEMSName
String
Yes.
objectType
notifications::ObjectType_T
Yes.
emsTime
globaldefs::Time_T
Yes.
neTime
globaldefs::Time_T
Yes.
isClearable
boolean
Yes.
Always set to false.
Always set to false.
perceivedSeverity
notifications::PerceivedSeverity_T
Yes.Always set to
PerceivedSeverity_T.PS_INDETERMINAT
E.
PerceivedSeverity_T.PS_INDETERMINAT
E.
layerRate
transmissionParameters::LayerRate_
T
T
Yes.
granularity
Granularity_T
Yes.
pmParameterNam
e
e
PMParameterName_T
Yes.
If the NE does not report the location,
If the NE does not report the location,
this field is empty.
pmLocation
PMLocation_T
Yes.
If the NE does not report the location,
If the NE does not report the location,
this field is empty.
thresholdType
PMThresholdType_T
No.
value
Float
Yes.
Unit
String
No.
5.3.7 Alarm
The following table lists the most common alarm messages.
If there is an alarm on an STS/VC4 CTP utilizing all ports of a DS1/E1 card, the alarm is reported with
the containing PTP as port 127. If an STS/VC4 SNC exists with one of the drop CTPs of the SNC using
all ports on a DS1/E1 card, and if there is an alarm on the STS CTP, Prime Optical reports the port
number of the containing PTP as 127.
For ONS 15454 and ONS NCS2K SONET and SDH, the virtual port details are displayed in
If there is an alarm on an STS/VC4 CTP utilizing all ports of a DS1/E1 card, the alarm is reported with
the containing PTP as port 127. If an STS/VC4 SNC exists with one of the drop CTPs of the SNC using
all ports on a DS1/E1 card, and if there is an alarm on the STS CTP, Prime Optical reports the port
number of the containing PTP as 127.
For ONS 15454 and ONS NCS2K SONET and SDH, the virtual port details are displayed in
additionalText for AR_XPE sync loss alarms.
Table 5-13: Alarm
Attribute Name
Type
Supported by Prime Optical?
notificationId
String
Yes. The uniqueness and sequence of
the notification ID are not guaranteed.
the notification ID are not guaranteed.
objectName
globaldefs::NamingAttributes_T
Yes.