Attribute Name
Type
Supported by Prime Optical?
nativeEMSName
String
Yes.
nativeProbableCause
String
Yes.
In case of external condition
In case of external condition
alarms, the string value of the
condition type is appended to this
field.
condition type is appended to this
field.
objectType
notifications::ObjectType_T
Yes.
emsTime
globaldefs::Time_T
Yes.
neTime
globaldefs::Time_T
Yes.
isClearable
Boolean
Yes. The value is always set to True.
layerRate
transmissionParameters::LayerRate_T Yes.
probableCause
String
Yes.
probableCauseQualifier String
Yes. Prime Optical provides the same
value as in the nativeProbableCause
field.
value as in the nativeProbableCause
field.
perceivedSeverity
notifications::PerceivedSeverity_T
Yes.
serviceAffecting
notifications::ServiceAffecting_T
Yes.
affectedTPList
globaldefs::NamingAttributesList_T
Yes.
additionalText
String
Yes.
additionalInfo
globaldefs::NVSList_T
Yes.
Prime Optical provides subnetwork
name when available.
If the alarmed object is OC-n PTP,
Prime Optical also includes
SDH_SONET_SS_BITS in this list.
Prime Optical provides the IP address
for ME-related alarms.
Prime Optical provides the ME name
when the object type is OT_EMS and
the alarm is ME-related.
Prime Optical provides Card Name
when available.
Prime Optical provides Module Type
when available.
Prime Optical provides Affected
Object when available.
Prime Optical provides subnetwork
name when available.
If the alarmed object is OC-n PTP,
Prime Optical also includes
SDH_SONET_SS_BITS in this list.
Prime Optical provides the IP address
for ME-related alarms.
Prime Optical provides the ME name
when the object type is OT_EMS and
the alarm is ME-related.
Prime Optical provides Card Name
when available.
Prime Optical provides Module Type
when available.
Prime Optical provides Affected
Object when available.
isPropagated
Boolean
Yes, but this field is always set to
False.
False.
aresFDN
String
Yes.
5.3.8 Heartbeat Event
Prime Optical generates a periodic heartbeat event and pushes the event to the notification channel. By
default, this function is disabled. You can configure the interval value through the Prime Optical Control
Panel. If the interval value is set to 0, the heartbeat event is disabled. By monitoring this event, the
northbound interface client knows whether the notification service is active. The type_name field contains
the NT_HEART_BEAT value under the fixed_header for this type of event. Filterable_data has only one
field, which is shown in the following table.
default, this function is disabled. You can configure the interval value through the Prime Optical Control
Panel. If the interval value is set to 0, the heartbeat event is disabled. By monitoring this event, the
northbound interface client knows whether the notification service is active. The type_name field contains
the NT_HEART_BEAT value under the fixed_header for this type of event. Filterable_data has only one
field, which is shown in the following table.