Cisco Prime Optical 10.6 GateWay/CORBA Programmer Reference Guide 
 
 
617
 
the HTTP server must be running on all naming service hosts. Enter ctmc4-u80, 
ctm7-u60
  In addition to these naming service hosts, Prime Optical registers itself with the local 
naming service. The local naming service port is 14005 and is bundled with Prime 
Optical. 
  Name Service Root IOR—Defines the location and name of the file that contains 
the naming service root Interoperable Object Reference (IOR). The IOR file must 
be accessible through the following HTTP call: http://name-server-IP-
address:80/namingroot.ior
. Enter /namingroot.ior
Step 4 
Restart the GateWay/CORBA service. 
6.7  Naming Conventions for Published GateWay/CORBA Objects 
GateWay/CORBA publishes two top-level objects: EMSSessionFactory and NotificationChannel. Prime 
Optical creates these objects and registers them with the CORBA name server.  
GateWay/CORBA creates naming contexts under the root as shown in Figure 6-1. The last context in the 
tree must have a different name. To change this value in the Prime Optical client GUI: 
Step 1 
Log into the Prime Optical client with the appropriate Prime Optical user access profile. 
Step 2 
In the Domain Explorer window, click the Domain node. 
Step 3 
In the Management Domain Properties sheet, click the Identification tab. 
Step 4 
In the EMS Domain section, look for EMS ID. The value of this field should be used as the 
“id” field for context, where “kind” equals “EMS.” The default value is CTM. By using 
different names, you can install multiple instances of Prime Optical and use a centralized 
naming server and repository. 
The following figure shows the naming scheme for GateWay/CORBA objects.