2  Change your PC’s IP address and subnet mask to correspond with the V6000 factory 
default IP address and subnet mask, shown in
 Table 2
. For details on changing the IP 
address and subnet mask of your PC, refer to Windows™ Online Help (Start>Help). 
3  Access the V6000 Embedded Web Server (see 
Chapter 6: Accessing the Embedded 
Web Server
). 
4  In the ‘Quick Setup’ screen (shown in 
Figure 3
), set the V6000 ‘IP Address’ and ‘Subnet 
Mask’ fields under ‘IP Configuration’ to correspond with your network IP settings
5  Click the Reset button and click OK in the prompt; the V6000 applies the changes and 
restarts. This takes approximately 2 minutes to complete. When the V6000 has finished 
restarting, the power LED on the front panel of the power supply unit is lit green. Any 
power supply malfunction results in the LED switching off. 
6  Disconnect your PC from the V6000 or from the hub / switch (depending on the 
connection method you used in Step 1). 
7  Reconnect the V6000 and your PC (if necessary) to the network. 
8  Restore your PC’s IP address & subnet mask to what they originally were. If necessary, 
restart your PC and re-access the V6000 via the Embedded Web Server with its new 
assigned IP address. 
Assign an IP Address Using the CLI 
First access the CLI using a standard Telnet application or using a serial communication 
software (e.g., HyperTerminal
TM
) connected to the V6000 RS-232 port (see 
Accessing the 
CLI
). Then assign the V6000 an IP address (see 
Assigning an IP Address
). 
Accessing the CLI 
To access the CLI via the Embedded Telnet Server, follow these 3 steps: 
1  Enable the Embedded Telnet Server: 
ƒ  Access the V6000 Embedded Web Server (see 
Chapter 6: Accessing the Embedded 
Web Server
). 
ƒ  Set the parameter ‘Embedded Telnet Server’ (under Advanced Configuration 
Network Settings Application Settings) to ‘Enable (Unsecured)’. 
ƒ Click 
the 
Reset button on the main menu bar; the Reset screen is displayed. 
ƒ Click 
the 
Reset button in the middle of the Reset screen with the Burn option 
selected; the V6000 is shut down and re-activated. A message about the waiting 
period is displayed. The screen is refreshed.