3com 900-0387-01 User Manual

Page of 28
 
 V6000 Analog Integrated Branch Office Solution Installation Guide V6000 Analog Integrated Branch Office Sol
18 
2  Use a standard Telnet application to connect to the V6000 Embedded Telnet Server. 
3  Login using the username (‘Admin’) and password (‘Admin’). 
To access the CLI via the RS-232 port, follow these 2 steps: 
1  Connect the V6000 RS-232 port (labeled I0I0), located on the CPU module of the V6000 
front panel, to either COM1 or COM2 RS-232 communication port on your PC with the 
supplied RS-232 cable. 
2  Use serial communication software (e.g., HyperTerminal
TM
) to connect to the  
V6000.  
Set your serial communication software to the following communications port settings: 
ƒ  Baud Rate: 
115,200 bps 
ƒ Data 
bits: 
ƒ Parity: 
 
None 
ƒ Stop 
bits: 
ƒ Flow 
control: Hardware 
The CLI prompt is available immediately. 
Assigning an IP Address 
To assign an IP address via the CLI, follow these 4 steps: 
1  At the prompt type ‘conf’ and press enter; the configuration folder is accessed. 
2  To check the current network parameters, at the prompt, type ‘GCP IP’ and press enter; 
the current network settings are displayed. 
3  Change the network settings by typing: ‘SCP IP [ip_address] [subnet_mask] 
[default_gateway]’ (e.g., ‘SCP IP 10.13.77.7 255.255.0.0 10.13.0.1’); the new settings 
take effect on-the-fly. Connectivity is active at the new IP address. 
 
This command requires you to enter all three network parameters (each 
separated by a space). 
4  To save the configuration, at the prompt, type ‘SAR’ and press enter; the V6000 restarts 
with the new network settings.