3com superstack ii hub 10 User Manual

Page of 8
 
Rear Panel Connection
 
11
 
Power Supply and Fuse
 
WARNING:
 
 Ensure that the power supply is disconnected before 
 
opening the fuse holder cover.
 
The Hub 10 Telco automatically adjusts to the supply voltage. 
 
The fuse is suitable for both 110V A.C. and 220-240V A.C. 
 
operation.
 
To change the fuse, release the fuse holder by gently levering a 
 
small screwdriver under the fuse holder catch. Only 2A 
 
anti-surge type fuses of the same type and manufacture as the 
 
original should be used with the Hub 10 Telco. Close the fuse 
 
holder.
 
AVERTISSEMENT:
 
 Assurer que l'alimentation soit débranchée 
 
avant d'ouvrir le couvercle du contenant du fusible.
 
L'unité s'ajuste automatiquement à la tension d'alimentation. 
 
Le fusible est convenable aux deux opérations 110 V C.A. et 
 
220-240 V C.A.
 
Pour changer le fusible, dégager le contenant du fusible en 
 
mettant doucement un petit tournevis sous l'arrêt de 
 
contenant du fusible. Seulement les fusibles de types 2A 
 
anti-transitoires du même type et fabricant que l'original 
 
doivent être utilisés.
 
WARNUNG:
 
 Vor dem Öffnen der Sicherungshalterung das Gerät 
 
vom Netzstrom trennen.
 
Das Gerät stellt sich automatisch auf die 
 
Versorgungsspannung ein. Die Sicherung ist sowohl für 110V 
 
A.C. wie für 220-240V A.C. geeignet.
 
Zum Auswechseln der Sicherung durch leichtes Heben mit 
 
einem kleinen Schraubenzieher die Abdeckungsklappe der 
 
Sicherungshalterung lösen. Sicherungen nur durch gleichen 
 
Typ und Wert wie die Originalsicherung ersetzen. Sicherung 
 
auswechseln und die Klappe der Sicherungshalterung wieder 
 
schließen.
 
12
 
Socket for Redundant Power System
 
Only connect a 3Com Redundant Power System, option 3C565047, to 
 
this socket. For details, follow the installation instructions in the guide 
 
accompanying the Redundant Power System.
 
13
 
Management Module or Advanced RMON Module Slot
 
The Hub 10 Telco can be fitted with an optional SuperStack II Hub 10 
 
Management Module or Advanced RMON Module. When the module 
 
has an IP/IPX address, you can then use SNMP management to manage 
 
the stack containing the unit.
 
CAUTION:
 
 Do not remove the Management Module blanking 
 
plate with the power still connected.
 
For instructions on installing either module in an Hub 10 unit, refer to 
 
the guide that accompanies the module. You will need to remove the 
 
blanking plate to reveal the slot for the module. 
 
If you subsequently remove the Management or Advanced RMON 
 
Module from the Hub 10 unit, you must replace the blanking plate to aid 
 
the circulation of cooling air and prevent the entry of dust and debris.
 
14
 
Hub Expansion Connectors
 
You can connect units together in a stack to form a single logical 
 
repeater. You need one Hub Expansion Cable (3C625) for each additional 
 
unit in the stack. The diagram below shows how you connect units 
 
together. Do not use two cables to connect any two units to each other 
 
- they will not work if you do this. 
 
Disconnect power from all units that will form part of the new 
 
stack.
 
 Connect the male hub expansion connector of one unit to the 
 
female hub expansion connector of the next unit. Repeat this process 
 
until all the units are connected together. Refer to 
 
 
 
 
 for 
 
the number of units allowed in a stack.
 
CAUTION:
 
 If you intend to rack or wall mount the units, 
 
connect the units after they have been mounted.
 
15
 
Disable On Boot Switch
 
This switch is located behind the blanking plate covering the 
 
Management Module slot, 
 
13
 
. The unit is shipped with this switch set to 
 
Enable. 
 
CAUTION:
 
 Do not disable ports unless you have a 
 
management module installed in the stack.
 
16
 
Management / Advanced RMON Module Power Cable 
 
Connector
 
This plug, located behind the blanking plate, provides power to an Hub 
 
10 Management Module or Advanced RMON Module, if fitted and 
 
connected. See the guide accompanying the module for installation 
 
instructions.
 
17
 
AUI Port
 
You can connect the unit to any 802.3 transceiver using an AUI cable 
 
(sometimes known as a transceiver cable or drop cable). Connect one 
 
end of the AUI cable to the AUI port on the rear panel of the unit and 
 
the other end to the AUI port on the transceiver. Engage the slide locks 
 
at both ends of the AUI cable. 
 
Ensure that SQE test is disabled.
 
18
 
Transceiver Module Slot
 
A variety of 3Com plug-in Transceiver Modules or the Bridge 
 
MicroModule can be installed in the Hub 10 Telco (see overleaf
 
 
 
for a list). 
 
Transceivers provide direct network connections to different media.
 
CAUTION:
 
 Do not remove the Transceiver Module blanking 
 
plate with the power still connected.
 
Ensure that SQE test is disabled.
 
To install a Transceiver Module, refer to the guide that accompanies it. If 
 
you subsequently remove the Transceiver Module, you must replace the 
 
blanking plate to aid the circulation of cooling air and prevent the entry 
 
of dust and debris.
 
19
 
Self-adhesive Pads
 
The Hub 10 Telco is supplied with 4 self-adhesive rubber pads. If the unit 
 
is to be part of a free standing stack, apply the pads to the underside of 
 
the unit; stick a pad in the marked area at each corner of the unit. Place 
 
the units on top of each other, ensuring that the pads of the upper unit 
 
locate with the recesses of the lower unit. 
 
Do not apply the pads if you intend to rack or wall mount the unit.
Correct fuse location
L’emplacement du fusible correct
Richtige Stellung der Sicherung
Spare fuse location - DO NOT USE
L’emplacement du fusible incorrect - NE PAS UTILISER
Falsche Stellung der Sicherung - NICHT VERWENDEN
 
Enable
 
TP ports on front panel are enabled on power up. They 
 
may be subsequently disabled via management software.
 
 Disable 
 
TP ports on front panel are disabled on power up until 
 
management software enables them. This is required for 
 
standby ports in resilient links.