ADC UTU-701C User Manual

Page of 82
Functional Description
 
 700-701-100-02
18
August 9, 2002
 UTU-701 and ETU-751 List 1
P
ERFORMANCE
 M
ONITORING
 
AND
 H
ISTORY
The UTU and ETU units provide extensive real time, non-disruptive monitoring of HDSL transmission 
performance parameters for all units in a circuit. Performance of the user interface ports is also monitored. Current 
cumulative counts of the past 24 hours and historical data in the form of 24-hour history (in 15-minute increments) 
and a 7-day history (in 24-hour increments) are available to assist in identifying problem sources during 
troubleshooting. See 
 for information on performance screens.
The monitored parameters are described in 
.
A
LARMS
The UTU and ETU units generate alarms for problem conditions on the HDSL transmission facility and at the 
local application interface. Alarms can be individually enabled or disabled as well as configured as a Major or 
Minor alarms. See “System Configuration” on 
 to configure alarms. See 
 to 
view alarm conditions.
The HDSL transmission and application interface alarms are described in 
Table 10.
Monitored HDSL Transmission and Interface Performance Parameters
Monitored Parameter
Description
HDSL Noise Margin
A measure of the ratio of signal power to noise power, in decibels (dB), at a receiver point. A value 
of 0 dB means that the predicted transmission BER is equal to 10
–7
.  A value of 6 dB means the 
predicted transmission BER is equal to 10
–10
. The Main menu status display continuously updates the 
margin value.
HDSL CRC-6
A six-bit word in every HDSL frame, representing a calculation based on all the bits in that frame. Any 
mismatch at the receiver, between the received CRC-6 and the one calculated, based on the received 
data in the frame, indicates that one or more bits were received in error. The units use this parameter 
to derive HDSL Errored Seconds (ES).
HDSL Loss of Sync Word 
(LOSW)
The unit has detected an error in one or more bits in six consecutive HDSL sync words. TS 101 135 
requires two consecutive sync words to be received without error to clear this condition. A LOSW 
condition generally indicates the loop is down, thus data cannot be transmitted.
Based on the monitored parameters, the LTU and NTU units derive the following performance parameters:
HDSL Errored Second (ES)
An interval of one second during which at least one CRC-6 error is detected at the incoming HDSL 
port or there is an LOSW condition.
HDSL Unavailable Second 
(UAS)
A second during which a loop is down.