ADC UTU-701C User Manual

Page of 82
700-701-100-02
 System 
Configuration
UTU-701 and ETU-751 List 1
August 9, 2002
 43
HDSL Span 1 Alarms
1
Type  
at 
the 
Config Alarms drop-down menu to display the Config Alarms HDSL Span 1 menu (
). 
Figure 27.
Config Alarms HDSL Span 1 Menu
2
Do the following for each interface option to be changed.
 
The fields displayed in the Config Alarms HDSL 
Span 1 menu
 
are described in 
.
Use the 
 or 
 
key to select the sub-menu item to be changed.
Use the 
 to toggle to the appropriate option or type in the correct information, then press 
 to select the option.
Table 20.
Fields Displayed in Config Alarms LTU and Config Alarms NTU Interface Menus
Field
Description
Loss of Signal (LOS)
Loss of signal at the G.703 input.
Loss of Frame Alignment (LFA)
Loss of frame alignment at the G.703 input.
Receive Alarm Indication Signal (AIS)
Alarm indication signal (unframed all ones) received at the G.703 input.
Remote Alarm Indication Signal (RAI)
Remote alarm indication signal received at the G.703 input (through A-bit). 
Loss of Clock (LOC)
Applies to loss of external clock when EXT timing is used. The external clock was lost for 
the previous second. This alarm is reset when the clock is active again.
1
SPACEBAR
ENTER