buell s1 lightning '97 Manual

Page of 7
 
5-12
 
Solenoid Hold-in Test
 
 With test leads still connected in the manner
specified in the previous 
SOLENOID PULL-IN TEST
 
discon-
nect solenoid “C” terminal/battery negative test lead at
battery negative end only; reconnect loose end of this
test lead to battery positive, instead.
 
 If pinion remains in
pull-in position, solenoid is working properly. If pinion does
not remain in pull-in position, solenoid should be replaced.
 
Solenoid Return Test
 
 With test leads still connected in the manner
specified at the end of the previous 
 
disconnect solenoid “50” terminal/battery positive
test lead at either end. 
 
If pinion returns to its original posi-
tion, the solenoid is working properly. If pinion does not return
to its original position, solenoid should be replaced.
 
DISASSEMBLY, INSPECTION 
AND REPAIR 
 
1.
 Remove field wire (22).
2.
 Remove thru-bolts.
3.
 Remove two end cover screws, O-rings,
and end cover.
 
Figure 5-10. Hold-In Test
Figure 5-11. Return Test
Battery
b0162x5x
“C” terminal
“50” terminal
Battery
b0163x5x
“C” terminal
“50” terminal
 
Figure 5-12. Removing the Thru-Bolts
Figure 5-13. Removing End Cover
4860
Thru-bolts
3548a
End cover
End cover 
screws (2)
 
5