Siemens MC35 User Manual

Page of 256
AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 129 of 256 
15.07.2002 
 
4.45  AT+CSNS  Single Numbering Scheme 
The AT+CSNS command enables the ME to accept incoming calls when no bearer capability infor-
mation is provided with the call, e.g. single numbering scheme calls or calls originitating from analog 
devices. 
The command must be set before the call comes. By default, when you do not modify the settings, 
all calls received without bearer element are assumed to be voice.  
Please note that you can use the command if PIN authentication has been done during current ses-
sion. The setting will be automatically saved when you power down the GSM engine with AT^SMSO.
 
Test command 
AT+CSNS=? 
Response 
+CSNS: (list of supported <mode>s) 
OK 
 
Read command 
AT+CSNS? 
Response 
+CSNS: <mode>
 
OK 
Write command 
AT+CSNS=[<mode>] 
 
Response 
Write command  
OK 
Parameters 
<mode>: 
 
Voice 
Each call received without bearer element is as-
sumed to be speech. 
 
 
Fax  
Each call received without bearer element is as-
sumed to be an incoming fax. 
 
 
Data 
Each call received without bearer element is as-
sumed to be a data call. 
Please take into account that the bearer service 
parameters set with AT+CBST apply to all data 
calls including those received without bearer ca-
pability. To avoid conflicts see Chapter 4.5. 
 
 
Reference 
GSM 07.07 
Note