AT Command Set
 
 
 
 
 
 
 
MC35_ATC_01_V05.00 
Page 198 of 256 
15.07.2002 
 
8.10  AT^SDLD  Delete the “last number redial“ memory 
Test command 
AT^SDLD=? 
Response 
OK 
 
Execute command 
AT^SDLD  
The execute command deletes all numbers stored in the LD memory. 
Response 
OK/ERROR/+CME ERROR 
 
Reference 
Siemens 
 
Note 
 
8.11  AT^SHOM  Display Homezone 
Test command 
AT^SHOM=? 
Response 
OK 
Parameter 
See execute command 
Execute command 
AT^SHOM 
Response 
TA returns homezone state 
^SHOM: <homezonestate> OK  
 
Parameters 
<homezonestate> 
ME is out of Homezone  
 
 
ME is within the Homezone 
Reference 
Siemens 
Note 
 
 
8.12  AT^SLCD  Display Last Call Duration 
Test command 
AT^SLCD=? 
Response 
OK 
Parameter 
See execute command 
 
Execute command 
AT^SLCD 
Response 
TA returns last call duration or current call duration 
^SLCD: <time> OK  
 
Parameter 
<time>  string type value; format is "hh:mm:ss", where characters indicate hours, 
minutes, seconds; e.g. 22:10:00 “22:10:00", 
max values are 9999:59:59 
 
Reference 
Siemens 
Note