3. Apply masking tape to the end of a 
⁵⁄₁₆" nut driver to help hold 
the gas orifice spud in the nut driver while changing it. Press 
nut driver down onto the gas orifice spud and remove by 
turning it counterclockwise and lifting out. Set gas orifice 
spud aside. 
4. Remove the cardboard orifice spud holder located on the 
back of the range near the gas inlet. Gas orifice spuds are 
stamped with a number, marked with 1 color dot, and have a 
groove in the hex area. Replace the Natural gas orifice spud 
with the correct LP gas orifice spud.
Refer to the following chart for correct LP gas orifice spud 
placement.
LP Gas Orifice Spud Chart for Standard Surface Burners
NOTE: Refer to the Model Number and Serial Number Plate 
located behind the left side of the storage or warming drawer for 
proper sizing of spuds for each burner location.
5. Place Natural gas orifice spuds in the cardboard orifice spud 
holder.
6. Replace the burner base using both screw.
7. Replace burner cap.
8. Repeat steps 1-7 for the remaining burners.
To Convert Oven Bake Burner
1. Remove oven racks.
2. Use a ½" combination wrench to turn the orifice hood down 
snug onto pin (about 2 to 2½ turns).
IMPORTANT: Do not overtighten.
The oven bake burner flame cannot be properly adjusted if 
this conversion is not made. See “Adjust Oven Bake Burner 
Flame” section.
To Convert Oven Broil Burner
Use a ½" combination wrench to turn the orifice hood down snug 
onto the pin (about 2 to 2½ turns).
IMPORTANT: Do not overtighten.
The oven broil burner flame cannot be properly adjusted if this 
conversion is not made. See “Adjust Oven Broil Burner Flame” 
section.
A. Orifice spud
B. Orifice spud holder
C. Screw
D. Spark electrode
A. Groove
Burner Rating
Color
Size
ID Number
12,000 BTU
11,000 BTU
 8,000 BTU
 5,000 BTU
Green/Magenta
Green/Yellow
Green/Lt. Blue 
Green/Brown
1.03 mm
0.99 mm
0.80 mm
0.65 mm
L103
L99
L80
L65
C
B
D
A
A
A. Orifice hood
B. Pin
C. Natural gas: increase gas - increase flame size 
(preset at factory for Natural gas)
D. LP gas: decrease gas - decrease flame size
A. Orifice hood
A
B
C
A
D
A