Enviro sienna indoor gas fireplace User Manual

Page of 32
Initial Installation
QUALIFIED INSTALLERS ONLY
D
IRECT
 V
ENT
 M
ODEL
:
WARNING: This appliance has been designed to draw room air for proper heat circulation 
from the sides of the unit.  Blocking or modifying the louvers in any way can create hazardous 
situations.
This model is vented with two (2) 3” aluminum or stainless steel flex vent leading into a co-linear to 
co-axial vent adaptor and using a vertical termination cap. The flue collars of this model will fit inside of 
standard 3” vent and may be fastened directly to the vent. The Exhaust vent is on the right of the flue 
connector. The Air Intake is on the left side of the vent collar plate (this outlet is not in the center, it is off 
to one side of the vent collar plate.)
Check  periodically  that  the  vents  are  unrestricted.  Also  ensure  that  all  direct  vent  pipes  have  been 
properly sealed and installed after routine inspection or cleaning. The air intake and exhaust pipes must 
be installed in the correct locations on the removable connector.
P
REPARING
 Y
OUR
 S
IENNA
 F
OR
 I
NSTALLATION
:
•  Remove  the  packaging  from  the  appliance  and  surround  panels;  check  to  make  sure  there  is  no 
damage. Carefully check the glass door. Do not use the unit if it is damaged. In the event damage is 
found, please report it to both the courier and your dealer as soon as possible. 
•  Carefully clean the fireplace and flue before installing the stove. Failure to do so may result in fumes 
or dirt being blown into the room and may cause a fire leading to death or serious injury.
1. Remove the unit from the box and remove all packaging material from the appliance.
2. Remove door. See M
AINTENANCE
 
AND
 S
ERVICE
 - G
LASS
 D
OOR
 R
EMOVAL
.
3. Remove log and ember set and all wrapping material from the stove. Remove wrapping material from 
log and embers and check for any damage. If damage is observed, do not use unit and contact your 
local dealer.
4. Remove the vent collar plate from the top of the stove by unscrewing the two (2) T-20 Torx screws 
located on the center top of the stove. Slide the collar plate backwards.  If the fireplace that the unit 
is to be installed into is high, the collar plate does not need to be removed. Properly secure the vent 
collar plate to the flexible vent pipe liner(s) previously installed in the chimney. Be careful not to over-
stretch the liner(s).
5. Place  the  unit  part  way  into  the  fireplace.  Connect  the  fireplace  insert’s  flexible  gas  line  to  the 
household gas supply, using locally approved methods. Place the electric cable so it can be connected 
to the power supply. 
15
6.  As  you  push  the  unit  into  its  final  position 
in  the  fireplace,  if  the  vent  collar  plate  was 
removed,  reinstall  it  to  the  stove  by  sliding 
it along the draft hood and secure with the 
screw. 
7.  Adjust  the  leveling  legs  to  ensure  the  unit 
is level. There are two (2) leveling legs on 
each side (shown in Figure 19).
Leveling Legs
two (2) on each side
Figure 19: Leveling legs position.