Enviro DV36 User Manual

Page of 40
21
Initial Installation
QUALIFIED INSTALLERS ONLY
V
ENTING
:
This fireplace has been tested and certified for use with SIMPSON DURAVENT DIRECT VENT TYPE “GS” 
PIPE FOR GAS STOVES, SECURITY CHIMNEY’S SECURE VENT DIRECT VENT SYSTEM kits, AMERICAN 
METAL PRODUCTS AMERIVENT DIRECT and DIRECT-TEMP SELKIRK METALBESTOS.
A 1” (25 mm) clearance to combustibles must be maintained around any vertical vent pipe. Around a 
horizontal vent pipe, the clearance to combustibles should be 2” (51 mm) above and 11⁄2” (38 mm) on the 
sides and bottom. When combustible materials are directly above a 90° elbow, 3” (76 mm) of clearance 
are necessary (see Figure 28).
Table 7. Vent Pipe Minimum Clearances.
Vertical Pipe to 
the Side Walls
Horizontal Pipe to 
the Sides & Bottom
Above an Elbow 
Above the Unit
Above an Elbow 
Not Above the Unit
Above Horizontal 
Vent Pipe
Wall Frame  8” 
(203mm) or less
Hard 
Pipe
1”
(25.4 mm)
11⁄2”
(38.1 mm)
3”
(76.2 mm)
3”
(76.2 mm)
2”
(51 mm)
10”x10”
(25x25cm)
Flex 
Pipe
1”
(25.4 mm)
11⁄2”
(38.1 mm)
8”
(203 mm)
4 3⁄8”
(111 mm)
4 3⁄8”
(111 mm)
10”x10”
(25x25cm)
A 10” (254 mm) x 10” (254 mm) frame (see Figure 29) will assure the proper support and spacing for 
the vent pipe as it passes through the wall. Installations in Canada require that a wall thimble be used 
for passing through walls and ceilings. All sealing and vapour barriers must comply with local building 
codes.
When planning an installation, it is necessary to select the proper 
length of vent pipe for the particular requirements. The configuration 
of  the  venting  pipes  depends  on  the  locations  of  walls,  ceilings, 
and studs.  However,  the  pipes  cannot  be  of  arbitrary  length and 
arrangement.  Because  the  length  of  the  vertical  and  horizontal 
Figure 28. Vent Pipe Clearances.
2" (51mm)
3" (76mm)
41
3
/
4
"
(1048mm)
Figure 29. Vent Framing For Wall or Ceiling.
Figure 30. Wall/Ceiling Thimble provided.
WARNING: This gas appliance must not be connected 
to  a  chimney  flue  serving  a  separate  solid-burning 
appliances.
sections 
dramatically 
affects  the  burning 
efficiency 
of 
the 
fireplace, 
certain 
guidelines 
have 
been  set  in  I
NITIAL
 
I
NSTALLATION
  -  V
ENT
 
C
ONFIGURATIONS
 
AND
 
R
ESTRICTOR
 S
ETTINGS
.   
A  two  (2)  piece  wall/
ceiling 
thimble 
is 
included with the stove 
(see Figure 30).
Venting  terminals  can 
not  be  recessed  into  a 
wall or siding.