Enviro DV36 User Manual

Page of 40
Figure 31. Possible Vent Configurations for Top Vented; Vertical 
and Horizontal Terminations.
Figure 32. Possible Vent Restrictor Positions.
Initial Installation
QUALIFIED INSTALLERS ONLY
V
ENT
 C
ONFIGURATIONS
 
AND
 R
ESTRICTOR
 S
ETTINGS
:
Figures 23 shows the range of venting options, it shows possible vent configurations if the unit is top 
vented,  for  vertical  and  horizontal  terminations,  any  layout  that  remains  within  the  shaded  area  is 
acceptable. Having the fewest number of elbows is ideal, as they tend to disrupt air movement. Using 
45˚ elbows is preferable to using 90˚ elbows. Also, a shorter vent system will perform better than a 
longer one.
The vent restrictor controls the amount of air moving through the vent pipe. Longer vertical vent lengths 
necessitate  greater  restriction;  position  1  is  open  and  position  5  is  maximum  restriction.  Figure  31 
NOTE: The total length of the vent pipes can 
not exceed 32 feet (15.12 m). Any combination 
of rise and run can be used as long as it lays 
within the shaded area (a total of three (3) 90° 
elbows or six (6) 45° elbows can be used). 
In  addition  to  what  is  shown,  if  a  90° 
elbow  is  used  in  the  horizontal  plane, 
3 feet (91.4 cm) must be subtracted 
from  the  allowable  horizontal  run 
(for  each  45°  elbow,  11⁄2  feet 
must  be  subtracted  from  the 
allowable horizontal run). 
shows the vent restrictor position required, 
relative  to  the  length  of  vent  pipe.  The 
vent  restrictor  is  located  in  the  center  of 
the  fireplace,  above  the  glass.  Figure  32 
shows the vent restrictor dial and the holes 
that indicate the different levels. To avoid 
injury,  it  is  best  to  make  this  adjustment 
when the fireplace is cool or use welder’s 
gloves or oven mitts.
Note:  0,0  in  Figure  31  represents  a  90˚ 
bend directly off the outlet of the unit, 413⁄4 
inches (106 cm) from floor, in all horizontal 
instances except when using Selkirk and 
having  less  than  a  4  feet  (1.22  m)  rise 
and  8  feet  (2.44  m)  horizontal  offset.  In 
this case, a 1 foot (30.5 cm) rise must be 
added below the 90˚ bend.
Note for rear vented: At 293⁄8 inches (75 
cm) up, the maximum horizontal rear exit 
vent length is 17 inches (43 cm) with a 45° 
elbow (see Figure 17).
22