Secondary Installation
O
PTIONAL
 C
ERAMIC
 B
RICK
 P
ANEL
 I
NSTALLATION
:
Turn off the gas control knob and allow the 
unit to cool.
Please ensure that your ceramic panels have not 
been damaged.
To Install Panels:
1.  Remove  the  glass  door  by  following  the 
instruction  in  the  “S
ECONDARY
  I
NSTALLATION
  - 
G
LASS
 D
OOR
 R
EMOVA
l” section and remove logs 
if necessary.
2. Slide center brick panel up behind the baffle 
(shown  in  Figure  49)  and  rest  the  bottom  of 
the panel on the ledge.
Figure 49.  Back Panel In Place.
Figure 50.  Right Panel In Place.
Figure 51.  Top Tab For Right Panel.
Figure 52.  Bottom Tab For Right Panel.
the  top  right  tab  tight  against  the  top  of  the  panel  (see 
Figure 51).
6. Repeat steps 4 and 5 for the left panel.
7. Install the log set (refer to S
ECONDARY
 I
NSTALLATION
 - L
OG
 S
ET
 
AND
 E
MBER
 I
NSTALLATION
) and glass door. 
To Remove Panels:
1. Pull the bottom and top tabs away from the side panels.
2. Carefully slide the side panels out towards the front, do not 
slide the panels on the tabs.
3. Push the center panel straight up about 1⁄4 inch (5 mm), 
pull the bottom out past the ledge, then pull the panel down 
until it is past the bottom of the baffle. Remove panel from 
firebox
3. Using a flat head screwdriver, bend the top tabs on either side at the front of the baffle down (refer to 
Figure 51 for placement).
4. Slide the right panel along the side of the firebox until it is tight against the right side of the center 
panel. Ensure the panel is behind the top tab (see Figure 50).
5. Bend up the right bottom tab until it touches the bottom of the right panel (see Figure 52) and press