Secondary Installation
QUALIFIED INSTALLERS ONLY
O
PTIONAL
 F
AN
 K
IT
 I
NSTALLATION
:
The  optional  fan  is  thermostatically  controlled  and  it  will  not  operate  if  the  appliance  is  cold.  A  few 
minutes after the appliance is lit and the variable speed control is set at a desired setting, the fan will 
automatically turn on. The fan will automatically turn off a few minutes after the appliance is shut off.
Kit Contents:
This kit includes a fan assembly (a fan within a box 
housing connected by a wire to the fan control box 
then ends at a three prong plug) and two (2) T-20 
torx screws.
Please  ensure  that  your  fan  kit  has  not  been 
damaged. If so, contact your dealer, distributor, or 
courier company before starting this installation.
Figure 53.  Wiring Diagram For Fan Control.
The  fireplace  must  be  electrically 
connected  and  grounded  in  accordance 
with  local  codes  or,  in  the  absence  of 
local  codes,  with  the  current  CSA  C22.1 
Canadian  Electrical  Code  Part  1,  Safety 
Standards  For  Electrical  Installations,  or 
The National Electrical Code ANSI / NFPA 
70 in the US.
WARNING:  The  electrical  grounding 
instructions  must  be  followed.  The 
fan  kit  is  equipped  with  a  three-prong 
(grounding)  plug  for  your  protection 
against  shock  hazard,  and  should  be 
plugged directly into a properly grounded 
three-prong outlet. DO NOT cut or remove 
the grounding prong from this plug.
CAUTION: When servicing controls, label 
all  wires  prior  to  disconnection.  Wiring 
errors can cause improper and dangerous 
operation.  Verify  proper  operation  after 
servicing.
Fan Control
Black
Black
Black
Black
Black
Black
White
White
White
Green/Yellow
Green
Green
White
120
o
F (49
o
C)
Temperature Sensor
Fan
Electrical Cord
E
le
ct
ric
al
P
ow
er
C
or
d
33
Figure 54. Placing Fan Kit Into DV36