A
IR
 S
HUTTER
:
Air Shutter Adjustment Nut
Figure 5: Air Shutter Adjustment.
The  air  shutter  is  controlled  by 
sliding  the  air  shutter  adjustment 
screw  (shown  in  Figure  5)  either 
forwards  or  backwards.  The 
adjustment  screw,  for  the  primary 
air, is located on the bottom of the 
firebox. The air shutter nut can be 
accessed  by  removing  the  control 
panel. This is best done during the 
initial installation.
Sliding  the  shutter  forwards 
increases  the  primary  air  while 
sliding  the  shutter  backwards 
decreases the primary air. 
The  air  shutter  allows  the  amount 
of air coming into the fireplace to be 
adjusted in order to accommodate 
different  climates  and  venting 
arrangements.  Start  the  pilot  and 
then the burner. Make sure the pilot 
flame is burning normally and none 
of the burner ports are plugged. Let 
the fireplace burn for roughly fifteen 
(15) minutes and then examine the 
flames,  compare  the  flames  to 
Figure 43 or Front Cover.
Operating Instructions
For Your Safety, Read Safety Precautions 
And Lighting Instructions Before Operating
Cara
On/Off
High
Low
Off
Fan
Remote Control Receiver
(optional)
Ignitor