Adjustments
Loading Door Switch
Non-CE Models
The door switch should be adjusted so the cylinder 
stops when door is opened 2 inches (51 mm) plus or 
minus 0.25 inch (6 mm). This switch is a normally 
open switch and is closed by the hinge cam when the 
door is closed. If adjustment is required, refer to 
Figure 16 and proceed as follows:
1. Close door and start tumbler, slowly open 
loading door. Cylinder and heat system should 
shut off when door is open 2 inches (51 mm) plus 
or minus 0.25 inch (6 mm).
2. Slowly close the loading door. When door is 
2 inches (51 mm) from being fully closed, the 
door switch actuating bracket (located on the 
door) should depress the button and the switch 
arm with an audible “click.”
3. If the actuating bracket does not operate the 
switch at the appropriate door closure, bend the 
actuating switch arm in or out to achieve proper 
actuation.
CE Models Through Serial No. 0208002174
CE tumblers have a second door switch near the top of 
the door (refer to Figure 16). This switch also should 
be adjusted so cylinder stops when door is opened 
within 0 – 2 inches (0 – 51 mm). This switch is 
normally closed and is opened by the hinge cam when 
the door is opened. If adjustment is needed, refer to 
Figure 16 and proceed as follows:
1. Remove lower switch actuator (Figure 16) so 
upper switch “click” can be heard.
2. Loosen upper door switch screws just enough so 
switch can be moved left and right. Move switch 
right if door opens too far before switch clicks. 
Move switch left if door doesn’t open far enough 
before switch clicks.
3. Retighten door switch screws and retest. Repeat 
step 2 if further adjustment is needed.
4. Reinstall lower switch actuator and retest its 
switch.
Figure 16 
T386I
1
CE Tumblers Only
2
Lower Switch Actuator
1
2