Specific Conversion Procedures
How to Convert Gas Valve from Regulated to 
Unregulated
NOTE: Conversion from regulated to unregulated 
is only needed when regulated tumblers were 
ordered, but unregulated tumblers were needed.
1. B-M gas valve:
(120 Pound Models)
Refer to Table 2.
a. Disconnect electrical power from tumbler. 
Close gas shut-off valve to tumbler. Refer to 
Figure 2.
b. Remove converter cover screw. Invert brass 
converter and install with breather hole down. 
Reinstall converter cover screw. Refer to 
Figure 4.
c. Change injector size as required by the 
appropriate table according to How to 
Change Injector (Orifice) Size
.
d. Commission tumbler for use.
2. Johnson GM2000 gas valve:
(170 Pound Models)
Refer to Table 3.
a. Disconnect electrical power from tumbler. 
Close gas shut-off valve to tumbler. Refer to 
Figure 2.
b. Loosen screws on regulator adjustment knob, 
then turn knob clockwise. When knob no 
longer turns, retighten screws. Refer to
Figure 3.
c. Change injector size as required by the 
appropriate table according to How to 
Change Injector (Orifice) Size
.
d. Commission tumbler for use.