How to Adjust Gas Valve Governor/Regulator
1. Check gas injector (manifold) pressure as 
follows. Refer to Figure 5.
2. Remove screw plug from inside pressure tap.
3. Connect a “U”-tube manometer (or similar 
pressure gauge) to the injector (manifold) 
pressure tap.
4. Start tumbler and note pressure once flame is 
burning. Remove regulator cap and adjust 
regulator screw until the injector pressure per 
applicable table is achieved. Replace regulator 
cap.
Figure 6 
T137K
1
Burner Tube Attaching Screws
6
Spud Holder Nut
2
Burner Support Bracket
7
Spud Holder
3
Pressure Tap
8
Pressure Tap (Alternate location)
4
Gas Valve
9
Manometer
5
Gas Valve Flange
1
2
4
3
5
6
7
8
9
REQUIRED 
INJECTOR 
PRESSURE
T025KE1D
1
Size Stamped on Orifice
T025K
1
BURNER INJECTOR
(ORIFICE)