Alliance Laundry Systems D677I User Manual

Page of 122
Installation
510969
42
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
A Backdraft Damper, Part No. 58786 (obtain locally), 
should be installed in a 4 inch (10.2 cm) diameter 
VERTICAL duct system. This will prevent a backdraft 
when dryer is not in use, and will keep the exhaust air 
in balance within the central exhaust system.
Lint Filter
CLEAN THE LINT FILTER BEFORE DRYING 
EACH LOAD. (Refer to Figure 33 for lint filter 
location.) Cleaning the lint filter is important because 
a layer or pad of lint on the filter will block the flow of 
air through the dryer, thus reducing the efficiency of 
the dryer. The clothes will take longer to dry and 
energy will be wasted.
Figure 33 
Motor Overload Protector
The motor overload protector stops the motor and 
shuts the heat off automatically in the event of an 
overload. After cooling, the overload protector will 
reset itself. The dryer can be restarted by pressing the 
PUSH-TO-START button. If the overload protector 
cycles again, remove the unit from use and call the 
service person to correct the problem.
Duct 
Station
Minimum Diameter of 
Collector Duct
A
4 inches (10.2 cm)
B
8 inches (20.3 cm)
C
9 inches (22.9 cm)
D
10 inches (25.4 cm)
E
11 inches (27.9 cm)
F
12 inches (30.5 cm)
G
13 inches (32.6 cm)
H
14 inches (35.6 cm)
I
15 inches (38.1 cm)
J
15 inches (38.1 cm)
K
16 inches (40.6 cm)
D608I
1
Lint Filter
D608I