Installation
800937
20
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Figure 25 
DO NOT OPERATE OTHER APPLIANCES ON 
THE SAME CIRCUIT. DO NOT OVERLOAD 
CIRCUITS!
Do not operate both a washer and gas dryer on the 
same circuit. Use separately fused 15 Amp circuits.
Electric Dryer
(120/240 Volt, 60 Hertz, 3-Wire Installation) 
(120/208 Volt, 60 Hertz, 3-Wire Installation)*
*Alternative Heating Element Required
NOTE: The wiring diagram is located behind the 
control panel, inside the control cabinet.
D799I
1
L1
2
Ground
3
Neutral Side
4
Round Grounding Prong
5
Neutral
    
1
3
4
2
120 ± 12
V.A.C.
0
V.A.C.
120 + 12
V.A.C.
STANDARD 120 VOLT, 60 HERTZ, 3-WIRE 
EFFECTIVELY GROUNDED CIRCUIT
5
To reduce the risk of electric shock or fire, 
DO NOT use an extension cord or an 
adapter to connect the washer to the 
electrical power source.
W031
WARNING
To reduce the risk of fire, electric shock or 
personal injury, all wiring and grounding 
MUST conform with the latest edition of 
the National Electrical Code ANSI/NFPA 70 
or the Canadian Electrical Code, CSA 
C22.1, and such local regulations as might 
apply. It is the customer’s responsibility to 
have the wiring and fuses checked by a 
qualified electrician to make sure the 
laundry room has adequate electrical 
power to operate the dryer.
W035
WARNING