Alliance Laundry Systems Stacked Drying Tumbler User Manual

Page of 38
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Installation Instructions
25
M412060
Instructions for Lighting and 
Shutting Down Instant Electronic 
Ignition System
1. Turn gas shut-off valve to “on” position (handle 
2. Start tumbler in drying cycle. Spark igniter will 
begin sparking as the gas valve simultaneously 
opens. The gas burner is ignited by the sparking 
igniter. The igniter will then shut off. Burner will 
remain on for as long as the temperature control 
calls for heat.
3. Opening the loading door will extinguish burner 
flames. Closing loading door and restarting 
tumbler should cause gas to be re-ignited.
4. If gas does not light, open and close loading door 
again and restart the ignition cycle.
IMPORTANT: The Instant Electronic Ignition 
system will attempt to light the gas by sparking for 
approximately 15 seconds. If gas does not ignite 
within 15 seconds, the Instant Electronic Ignition 
control will go into safety lockout (if this occurs, the 
red light on the IEI board will be illuminated). The 
valve will not open until the Instant Electronic 
Ignition control is reset. Reset by opening and 
closing the loading door.
If condition persists, check that the gas shut-off 
valve is open and that gas service is properly 
connected. If condition still persists, remove 
tumbler from service.
5. To remove tumbler from service, disconnect 
electrical service and turn gas shut-off valve to 
“off” position (handle at right angle to gas line). 
Refer to Figure 12.
Figure 12
Off 
Position
On 
Position
TMB2162N
Gas
Line