Installation        7
PressuresettingInstructions
Pressure Setting Instructions:
1. alwayssetthekickoutpressuresettingfirst. 145 psi minimum/150 psi maximum.
2. After kick out pressure is set, adjust the kick on screw setting at 115 psi minimum/120
psi maximum.
3. Cycle compressor to verify correct settings.
4. For questions about this procedure, please contact Stellar Customer Service.