Siemens stober combidrive cm150-3 User Manual

Page of 40
6.  Specifications
English
© STÖBER plc 1997
29
05.02.01
6.  SPECIFICATIONS
CSA-single-phase device
Model
PM25/1
PM37/1
PM55/1
PM75/1
Motor frame size:
4 pole
71K
71L
80K
80L
Motor output rating:
0.25 kW
0.37 kW
0.55 kW
0.75 kW
Operating input voltage:
1ø AC  208 - 240 V
rms
 ± 10%
Operating input frequency:
47 - 63 Hz
Output frequency:
0 - 150 Hz
Output frequency with.
OPm2 or serial link:  
4 pole
0 - 140 Hz
0 - 140 Hz
0 - 140 Hz
0 - 140 Hz
Input current:
3.2 A
rms
4.6 A
rms
6.2 A
rms
8.2 A
rms
Main fuse:
10 A
16 A
Min lead cross-section:
1 mm2
1.5 mm2
CSA-three-phase device
Model
PM37/3
PM55/3
PM75/3
PM110/3
PM150/3
Motor frame size:
4 pole
71L
80K
80L
90S
90L
Motor output rating:
0.37 kW
0.55 kW
0.75 kW
1.1 kW
1.5 kW
Operating input voltage:
3ø AC  380 - 480 V
rms
 ± 10% (all units)     3ø AC  460 - 500 V
rms
 ± 10% (unfiltered only)
Operating input frequency:
47 - 63 Hz
Output frequency:
0 - 50 Hz
Output frequency with.
OPm2 or serial link:  
4 pole
140 Hz
140 Hz
140 Hz
140 Hz
140 Hz
Input current:
2.2 A
rms
2.8 A
rms
3.7 A
rms
4.9 A
rms
5.9 A
rms
Main fuse:
10 A
Min lead cross-section:
1 mm2
CSB-three-phase device
Model
PM220/3
PM300/3
PM400/3
PM550/3
PM750/3
Motor frame size:
4 pole
100K
100L
112M
132S
132M
Motor output rating:
2.2 kW
3.0 kW
4.0 kW
5.5 kW
7.5 kW
Operating input voltage:
3ø AC  380 - 480 V
rms
 ± 10% (all units)     3ø AC  460 - 500 V
rms
 ± 10% (unfiltered only)
Operating input frequency:
47 - 63 Hz
Output frequency:
0 - 50 Hz
Output frequency with.
OPm2 or serial link:  
4 pole
140 Hz
140 Hz
140 Hz
140 Hz
140 Hz
Input current:
4.7 A
6.4 A
10.0 A
12.2 A
16.0 A
Main fuse:
10 A
16 A
20 A
Min lead cross-section:
1 mm2
1.5 mm2
2.5 mm2