Alliance Laundry Systems 504523R3 User Manual

Page of 82
504523
31
Additional Dryer Security . . .
(Metered Models)
Enclosed in the shipping bag are four tamper-resistant 
screws.  When used, these screws will provide additional 
security for your dryer.
Located on the service door of the dryer is a flat Phillips 
head screw.  During shipment, this screw is used to attach 
the service door to the meter case.  For additional 
security, this screw can be reinstalled inside the control 
hood of your washer.
The following list is the procedure required to install the 
Phillips head screw and tamper-resistant screws:
1. Remove the Phillips head screw from service door 
(see illustration).
2. Remove two screws holding control panel to control 
hood.
3. Tilt control panel forward and lay on a protective pad 
to prevent scratching of cabinet top.
4. Insert phillips head screw down through double “D”  
hole in left rear corner of cabinet top (inside control 
hood) until it engages retainer nut located on left rear 
corner gusset of cabinet.
5. Finger tighten screw.
IMPORTANT: Do not use a power driver to tighten 
screw.  Torque of a power driver could over-tighten 
screw causing damage to cabinet assembly.
6. Secure control panel to control hood using two No. 8 
tamper-resistant screws, Part No. 35528.
7. While supporting lower access panel, remove two 
screws from bottom edge.  Gently lower access panel 
to disengage guide lugs from bottom edge of front 
panel.
8. Remove two screws holding bottom tabs on front 
panel to dryer cabinet.  Swing bottom of front panel 
away from dryer far enough to disengage hold-down 
clips and guide lugs from cabinet top.
9. Disconnect wires from door switch.
NOTE: Refer to wiring diagram when rewiring 
switch.
10. Remove two cabinet top hold-down scerws and 
install two #10 tamper-resistant screws, Part No. 
62853.
11. Reinstall door switch and front panel and install two 
#10 tamper-resistant screws, Part No. 62853 to 
secure lower access panel.
NOTE: Tamper-resistant bits and bit holder, for 
installation of tamper-resistant screws, are available 
as optional equipment at extra cost.
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the dryer 
before servicing.
• Never start the dryer with any guards/
panels removed.
• Close gas shut-off valve to gas dryer before 
servicing.
• Whenever ground wires are removed 
during servicing, these ground wires must 
be reconnected to ensure that the dryer is 
properly grounded.
W138
WARNING
DOUBLE
“D” HOLE
#8 SCREWS
35528
#10 SCREWS
62853
#10 SCREWS
62853
D237IE1A
Bit (No. 8 screws) ................... Part No. 281P4
Bit (No. 10 screws) ................. Part No. 282P4
Bit Holder (3/8 drive).............. Part No. 24161